TROUBLESHOOTING
Dough sticks on the back roller
Cause
Remedy
The dough is too wet
Make new dough with less amount of water
Dough will not stick on front roller
Cause
Remedy
The metal straps do not rotate with the
roller
The metal straps must be firmly tightened to the roller
The dough is too dry
Add more water to the dough
The dough may not be special for corn
tortillas
Make dough using nixtamalized corn flour or nixtamalized
corn dough
Incorrect installation of the release wire.
The release wire must be in between the black rollers and
the metal straps.
The metal straps are not installed correctly.
The metal straps must be firmly tightened to the roller
The tail end of the metal straps must be completely bended.
The tortilla cutter does not cut tortillas
Cause
Remedy
The tortilla cutter is not installed correctly
Adjust the bolts in the tortilla cutter brackets
The tortilla cutter is not in working
condition
With #200 grit sand paper, sand the 3D edge of the round
shape of the tortilla cutter.
Change the tortilla cutter
The release wire breaks constantly
Cause
Remedy
The release wire is too tight
Loosen the wire slightly
It is not the recommended wire
Use the correct wire
The metal straps are not clean
i.
Clean the metal straps every day by running the
machine for about 5 minutes.
ii.
Clean with a damp cloth
The tortillas drop below the back roller into the base plate
Cause
Remedy
The rollers are separated too much
Adjust rollers to make tortillas from 1/16 to 1/8 of an inch
The dough is too dry
Make new dough with more water
The tortilla cutter is not in working
condition
Change the tortilla cutter
The tortillas have holes
Cause
Remedy
The dough is not well mixed
Mix the dough correctly
The dough ball is more than 1.5 Lbs.
Feed the Ventura Flex with dough balls no more than 1.5
lbs.
The dough is too dry
Make new dough with more water
Machine is not working
Cause
Remedy
The machine does not start
Pull the Emergency Stop Red Button.
Verify the 3 covers are closed.
Check the fuse is in working conditions
Overload motor protector is tripped
Check the building’s electrical source.
Wait 5 minutes and restart the machine
To buy extra metal straps, release wires and other parts, contact Tortilla Masters Equipment at 281 -994-7010
Содержание 105 VENTURA FLEX PL