TM INDUCTION HEATING
9
ST 2.0 |
Should an error occur during the heating process, the induction heater will
automatically stop. The corresponding error will be displayed on screen.
In the case of user error, the display indicates what steps are to be taken
to correct the problem. More information about the types of errors can
be found in chapter 7 -
ERRORS
.
An induction heater produces an electromagnetic field within a coil to
transfer energy to a workpiece. The table below shows values of the flux
density in microTesla (µT). These measurements can be used as a guide
conforming to local regulations regarding
the maximum time exposure to magnetic
fields. Different configurations may give
different values. It is impossible to provide
values for all combinations as the variety
of bearing types in combination with the
different yokes is large.
Total 50Hz RMS field for magnetic measurement results. Max. magnetic
flux in safe exposure area, according to the German BG 11 Regulations
is 423
µT.
SAFETY
FEATURES
MP1x
81
249
283
MP2x
16
34
74
MP3x
1
11
28
MP1y
156
181
185
MP2y
27
24
78
MP3y
9
9
41
Measurement position (cm)
B-field
total
(µT)
MP2x
60
MP1x
30
MP3x
90
30
60
90
MP1y
MP2y
MP3y
X
(cm)
Y
(cm)
Содержание SURETHERM 10X
Страница 1: ...ISO 9001 2008 ID 9108623968 www tuv com User Manual...
Страница 4: ...TM INDUCTION HEATING 4 ST 2 0...
Страница 35: ...user manual SURETHERM version 2 0 2017...
Страница 36: ......