1
ThermoBarScan
TM Electronics UK Ltd
INSTRUCTION BOOKLET
Страница 1: ...1 ThermoBarScan TM Electronics UK Ltd INSTRUCTION BOOKLET...
Страница 2: ...tware CD Place the CD into the CD drive of your PC or laptop The CD should Autorun and install If not please select setup and follow these instructions Click next to install the software You will then...
Страница 3: ...s the Bluetooth Button the word BLUE will be displayed in the top right hand corner This means that the instrument is now in Bluetooth mode and ready to connect to your TME software The instrument mus...
Страница 4: ...software will try to connect to each in turn retrieving their name and serial number these will be marked as Found If the connection is unsuccessful the instrument will be marked Not Found To connect...
Страница 5: ...er address will appear in the field below to indicate that the devices are paired The devices are now ready for use Note you can create a print header in the Setup tab Printing from your paired instru...
Страница 6: ...to computer with the cable provided Press the Bluetooth button USB will appear on display Click on the Discover Serial Ports Button Select the appropriated USB Serial Port and the instrument will aut...
Страница 7: ...le sets the temperature scale e g C F 4 Set Instrument Name allows you to identify the instrument with its own specified name 5 Set Print Header allows you to assign a heading for the print reports wh...
Страница 8: ...arcode formats All UPC EAN JAN Codes EAN28 Codes Code 39 Code 128 Interleave 25 PDF417 QR Code Data Matrix GS1 DataBarTM RSS RSS Limited RSS 14 RSS 14 Stacked RSS Expand For generating 2D or QR Codes...
Страница 9: ...ement Scan the barcode when read the instrument will Bleep When the Barcode has been read the temperature Barcode information Date and Time will be logged to the internal memory Up to 1000 readings ca...
Страница 10: ...Screen Data clears downloaded data from software 2 Latest scan displays the latest scan 3 Live data displays the instruments data in real time scan no serial number time date temperature temperature s...
Страница 11: ...ab and download your data as before Select Save File button In the box that appears select where you wish to save the data type in a file name and click save Your data will be saved as a CSV comma sep...
Страница 12: ...nually To enter manually type in the barcode followed by the product description When complete this information may be saved to a file and reloaded for subsequent downloads Once you have listed your i...
Страница 13: ...ll firstly need to connect your Barcode Printer to the software Select the Print Barcodes tab and click the Discovery button You will find that the printer s address has been listed in the Printer Add...
Страница 14: ...ues If these alarm values are exceeded a visual alarm will be shown on the thermometer display For example if a barcode represents a cooked chicken then set the low alarm value to 73 C and the high to...
Страница 15: ...enter your product barcode text which you would like to assign the alarms to followed by the high alarm limit and low alarm limit Select Upload Alarms to Instrument The alarm values are now assigned t...
Страница 16: ...ws the user to set a master alarm to the instrument Select Click Here To Set Global Alarm This will display the Global alarm fields Enter the high alarm and low alarm field and select Upload Global Al...
Страница 17: ...to Instrument Your instrument will now be set to alert you if the temperature falls between 20 C and 50 C by displaying LEG Other functions in the Alarms tab 1 Open Alarm File opens an existing csv fi...
Страница 18: ...digit spaces after the defining limits are laid out in this order Hundreds Tens Units Decimal For example 60 C High Alarm Limit and 30 C Low Alarm Limit will be entered as H0600L0300 250 C High Alarm...
Страница 19: ...ere to Generate Alarm Barcodes This will display the fields required for generating your alarms To generate a barcode with high and low alarms enter your high limit and low limit and then select Gener...
Страница 20: ...he high alarm limit and the capital B stands for the low alarm limit Each of the 4 digit spaces after the defining limits are laid out in this order Hundreds Tens Units Decimal To set Legionella Alarm...
Страница 21: ...scanned the display of the device will indicate whether the temperature taken is above or below the alarm limits The display will then revert back to a normal temperature display Deleting Alarms Alarm...
Страница 22: ...ts LEG Outside of safe Legionella temperature limits nOAL No alarm assigned to Barcode When data is downloaded to the TME software using the Download Data tab the following codes apply H AL High Alarm...
Страница 23: ...ute timer or 2 for 2 minute timer For example For 1 minute timer hot water the barcode could be For 2 minute timer cold water the barcode could be To take your readings using the timer first scan your...
Страница 24: ...downloaded data Please contact our sales team on 01903 700651 or sales tmethermometers com for guidance and advise Additional Information Please note that we recommend re setting the time and date whe...