― 10 ―
English
During Disassembly
During Reassembly
Remove gasket and clean sealing
surfaces
Replace with a new gasket, coat
surfaces with anti-seize
Remove without bending
Reinstall without bending
Remove, being careful not to scratch
sealing surfaces of body and cover
Make sure there are no pieces of old gasket
left on the sealing surface of body and
cover, then reattach
Insert into body, being careful not to
scratch its polished surface
Remove gasket and clean sealing
surfaces of cover and body
Remove only if corroded or
damaged
Reinstall with a Phillips screwdriver, then
tighten to the proper torque
Reattach without bending
Coat threads with anti-seize, then tighten
to the proper torque
Replace with a new gasket, do not apply
anti-seize
Remove, being careful not to scratch
its polished surface
Replace with a new bolt if corroded or
damaged
Replace with a new gasket, do not
apply anti-seize
Remove with a Phillips screwdriver
Remove without bending
Remove with a socket wrench
Remove gasket and clean sealing
surfaces
Coat threads with anti-seize, then tighten
to the proper torque
Remove with a hex wrench.
Part & No.
Screen Holder
Gasket 13
Screen 11
Cover 2
Cover Gasket 8
Float 3
Screw with Spring
Washer 7
Air Vent Strip 6
Orifice 4
Orifice Gasket 5
Coat threads with anti-seize, then tighten
to the proper torque
Remove with a socket wrench
Plug 16
Replace with a new gasket, coat surfaces
with anti-seize
Remove gasket and clean sealing
surfaces
Plug Gasket 17
Cover Bolt 9
Cover Nut 10
Remove with a socket wrench
Coat threads with anti-seize, then tighten
to the proper torque
Screen
Holder 12
Disassembly/Reassembly
(to reassemble, follow procedures in reverse)
Operational inspections should be performed at least twice per year, or as called for by trap
operating conditions. Steam trap failure may result in a temperature drop in the equipment, poor
product quality or losses due to steam leakage.
6. Inspection and Maintenance
WARNING
NEVER apply direct heat to the float. The float may explode due to
increased internal pressure, causing accidents leading to serious injury or
property and equipment damage.
• Installation, inspection, maintenance, repairs, disassembly, adjustment
and valve opening/closing should be carried out only by trained
maintenance personnel.
• Before attempting to open the trap, close the inlet and outlet isolation valves and wait until the
trap has cooled completely. Failure to do so may result in burns.
• Be sure to use the proper components and NEVER attempt to modify the product.
CAUTION
Body, Cover
Gaskets
Air Vent Strip
Screen
Float
Orifice
Check inside for damage, dirt, grease, oil film, rust or scale
Check for warping or damage
Check for damage
Check for clogging, corrosion or damage
Check for deformation, damage, oil film or water inside
Check for rust, scale, oil film, wear or damage
Parts Inspection Procedure