Страница 1: ...172 65464MA 02 JH8R B 18 November 2020 Free Float Steam Trap JH8R B Copyright 2020 by TLV CO LTD All rights reserved ...
Страница 2: ...nge less and lever less free float to rapidly automatically and continuously discharge the inflowing condensate that is continuously generated inside the equipment thus preventing the accumulation of condensate and thereby improving the heat transfer efficiency of the equipment In addition the integral bimetal type automatic air vent allows for the rapid release of start up air and thereby reduces...
Страница 3: ...oses a threat of death or serious injury WARNING Indicates that there is a potential threat of death or serious injury CAUTION Indicates that there is a possibility of injury or equipment product damage WARNING NEVER apply direct heat to the float The float may explode due to increased internal pressure causing accidents leading to serious injury or damage to property and equipment CAUTION Install...
Страница 4: ...discharge of fluids causing burns other injuries or damage Be sure to use only the recommended components when repairing the product and NEVER attempt to modify the product in any way Failure to observe these precautions may result in damage to the product and burns or other injury due to malfunction or the discharge of fluids Use only under conditions in which no freeze up will occur Freezing may...
Страница 5: ...pressure has a check valve TLV CK been installed 5 Is the inlet pipe as short as possible with as few bends as possible and installed so the liquid will flow naturally down into the trap 6 Has the piping work been done correctly as shown in the figures below Requirement Correct Incorrect Install catchpot with the proper diameter Diameter is too small Make sure the flow of condensate is not obstruc...
Страница 6: ...nflowing condensate causes the float to rise due to buoyancy opening the orifice B and allowing condensate to be discharged The air vent valve will remain closed throughout normal operation due to the high operating temperatures 3 Discharge of Large Quantities of Condensate Increases in the condensate inflow rate cause the condensate level in the trap to rise The float consequently rises and enlar...
Страница 7: ...e Maximum Operating Temperature Nominal Diameter Maximum Differential Pressure Valve No Production Lot No Maximum allowable pressure PMA and maximum allowable temperature TMA are PRESSURE SHELL DESIGN CONDITIONS NOT OPERATING CONDITIONS Valve No is displayed for products with options This item is omitted from the nameplate when there are no options Configuration No Name M R 6 Outlet Cover Gasket 7...
Страница 8: ...dischargeof fluids CAUTION Installation inspection maintenance repairs disassembly adjustment and valve opening closing should be carried out only by trained maintenance personnel 1 Before installation be sure to remove all protective seals 2 Before installing the product open the inlet valve and blow out the piping to remove any piping scraps dirt and oil Close the inlet valve after blowdown 3 Wh...
Страница 9: ...kage Normal Condensate is discharged continuously together with flash steam and the sound of flow can be heard If there is very little condensate there is almost no sound of flow Blocked Discharge Impossible No condensate is discharged The trap is quiet and makes no noise and the surface temperature of the trap is low Blowing Live steam continually flows from the outlet and there is a continuous m...
Страница 10: ...procedures to remove components Use the same procedures in reverse to reassemble Installation inspection maintenance repairs disassembly adjustment and valve opening closing should be carried out only by trained maintenance personnel Drain Plug Part During Disassembly During Reassembly Drain Plug Remove with a socket wrench Consult the table of tightening torques and tighten to the proper torque D...
Страница 11: ...Ring Pinch insides together and remove from the body Insert securely into the groove in the body Screen Remove by grasping the wire ring and lifting straight up and out Set the screen on the screen holder and screen holder retainer and insert as far as the snap ring groove Screen Holder Retainer Remove without bending Place on the screen holder without tilting Screen Holder Remove without bending ...
Страница 12: ...th anti seize If drawings or other special documentation were supplied for the product any torque given there takes precedence over values shown here 1 N m 10 kg cm Exploded View Cover Nut Cover Cover Gasket SnapRing Screen ScreenHolder Retainer ScreenHolder Float Bimetal Plate Air Vent ValvePlug Air Vent ValveSeat Air Vent Case Air Vent Guide Air Vent GuideGasket Cover Bolt Body Outlet Cover Bolt...
Страница 13: ... affixes the gasket tightly to the plug holder Check to make sure the gasket is not caught in the recesses of the threads 5 Hold the plug holder upside down to make sure that the anti seize makes the gasket stick to the plug holder even when the plug holder is held upside down 6 Screw the plug holder by hand into the product body while making sure that the gasket remains tightly affixed to the cen...
Страница 14: ... pressure exceeds the maximum specified pressure or whether there is insufficient pressure differential between the trap inlet and outlet Compare specifications and actual operating conditions Steam is discharged or leaks from the outlet blowing steam leakage Build up on the seating surface of the orifice or rust and scale build up beneath the float Clean parts Scratches on the orifice Replace wit...
Страница 15: ...oper installation use handling etc by other than TLV CO LTD authorized service representatives 2 Malfunctions due to dirt scale rust etc 3 Malfunctions due to improper disassembly and reassembly or inadequate inspection and maintenance by other than TLV CO LTD authorized service representatives 4 Malfunctions due to disasters or forces of nature 5 Accidents or malfunctions due to any other cause b...
Страница 16: ...MA 02 JH8R B 18 Nov 2020 15 Options The options shown below are available for this product on request Please compare with the product you received Options for Area A standard with drain plug Without Drain Plug A ...