172-65120MA-13 (CK-Series) 24 Aug 2020
4
Minimum Opening Differential Pressure by Direction of Fluid Flow
Flow Direction
Model
Horizontal
Vertical : Upward
Vertical : Downward
MPa [kPa] (psi)
MPa
[kPa]
(psi)
MPa
[kPa]
(psi)
CK3M/CK3T/CK3R
0.002
[2]
(0.3) 0.0015 [1.5] (0.22) 0.0025 [2.5] (0.40)
CK3T-M
Size
mm (in)
15 (
1
/
2
)
0.007
[7]
(1)
0.0065
[6.5] (0.94) 0.0075 [7.5] (1.10)
20, 25 (
3
/
4
,1)
0.005
[5]
(0.75) 0.0045
[4.5] (0.65) 0.0055 [5.5] (0.80)
CK3MG
0.001
[1]
(0.15) 0.0005
[0.5] (0.07) 0.0015 [1.5] (0.22)
CKF3M/CKF3R
0.002
[2]
(0.3) 0.0016
[1.6] (0.23) 0.0024 [2.4] (0.35)
CKF3MG/CKF3RG
0.001
[1]
(0.15) 0.0005
[0.5] (0.07) 0.0015 [1.5] (0.22)
Cv Values
Size
Mode
l
mm
15
20
25
32
40
50
65
80
100
(in)
(
1
/
2
)
(
3
/
4
)
(1)
(1
1
/
4
)
(1
1
/
2
)
(2)
(2
1
/
2
)
(3)
(4)
CK3M/
CK3T/
CK3R
Cv (US)
3.7
6.6
10
15
21
29
—
Cv (UK)
3.1
5.5
8.3
13
17
24
Kvs (DIN)
3.2
5.7
8.6
13
18
25
CK3T-M
Cv (US)
3.7
6.6
10
—
Cv (UK)
3.1
5.5
8.3
Kvs (DIN)
3.2
5.7
8.6
CK3MG
Cv (US)
—
25
—
55
91
—
180
—
Cv (UK)
21
46
76
150
Kvs (DIN)
21
47
78
154
CKF3M/
CKF3R
Cv (US)
4.6
8.8
16
20
29
—
Cv (UK)
3.8
7.3
13
17
24
Kvs (DIN)
3.9
7.5
14
17
25
CKF3MG
Cv (US)
—
54
100
140
240
Cv (UK)
45
83
117
200
Kvs (DIN)
46
85
120
206
CKF3RG
Cv (US)
—
54
—
Cv (UK)
45
Kvs (DIN)
46
Connectable Flange Standards
(This applies to the flangeless connections; CKF3M, CKF3R, CKF3MG and CKF3RG)
Size
JIS
ASME / JPI
PN (EN/DIN)
BS TABLE
mm
(in)
15
(
1
/
2
)
5,10,16,20,30K
Class 150,300
PN 6,10,16,25,40
A,D,E,F,H,J
20
(
3
/
4
)
25
(1)
Class
125,150,250,300
32
(1
1
/
4
)
40
(1
1
/
2
)
50
(2)
65
(2
1
/
2
)
F,H,J
80
(3)
10,16,20,30K
A,D,E,F,H,J
100
(4)
PN 10,16,25,40
Options
Model
∆P Minimum Opening Differential Pressure
CK3M/CK3T/CK3R
MPa
0.001, 0.01, 0.02
(psi)
(0.15, 1.5, 3)
CKF3M/CKF3R
MPa
0.001, 0.01*
(psi)
(0.15, 1.5*)
*Except nominal size of 40 mm (1
1
/
2
in) for
∆P 0.01 MPa (1.5 psi).
Model
Rubber Sealing Material
CK3R
Fluorine Rubber (FPM)
— TMO 150 °C (302 °F)
Special use
As a vacuum breaker*
*CK3R, CKF3R and CKF3RG (with rubber sealing) should not be used.
Due to the nature of the rubber, there is a possibility of the disc sticking to the metal valve seat,
compromising product performance at the very low differential pressures under which vacuum
breakers operate.