background image

 

172-65634MAJ-03  (A-DR20)    6  Oct  2021

 

18

 

REPORTED TO THE SELLER IN WRITING WITHIN THE WARRANTY PERIOD, 
INCLUDING A DETAILED WRITTEN DESCRIPTION OF THE CLAIMED DEFECT AND 
HOW AND WHEN THE CLAIMED DEFECTIVE PRODUCT WAS USED; AND (b) THE 
CLAIMED DEFECTIVE PRODUCT AND A COPY OF THE PURCHASE INVOICE IS 
RETURNED TO THE SELLER, FREIGHT AND TRANSPORTATION COSTS PREPAID, 
UNDER A RETURN MATERIAL AUTHORIZATION AND TRACKING NUMBER ISSUED BY 
THE SELLER. ALL LABOR COSTS, SHIPPING COSTS, AND TRANSPORTATION COSTS 
ASSOCIATED WITH THE RETURN OR REPLACEMENT OF THE CLAIMED DEFECTIVE 
PRODUCT ARE SOLELY THE RESPONSIBILITY OF BUYER OR THE FIRST END USER. 
THE SELLER RESERVES THE RIGHT TO INSPECT ON THE FIRST END USER’S SITE 
ANY PRODUCTS CLAIMED TO BE DEFECTIVE BEFORE ISSUING A RETURN MATERIAL 
AUTHORIZATION. SHOULD 

SUCH INSPECTION REVEAL, IN THE SELLER’S 

REASONABLE DISCRETION, THAT THE CLAIMED DEFECT IS NOT COVERED BY THIS 
WARRANTY, THE PARTY ASSERTING THIS WARRANTY SHALL PAY THE SELLER FOR 
THE TIME AND EXPENSES RELATED TO SUCH ON-SITE INSPECTION. 

Exclusion of Consequential and Incidental Damages 

IT IS SPECIFICALLY ACKNOWLEDGED THAT THIS WARRANTY, ANY OTHER EXPRESS 
WARRANTY NOT NEGATED HEREBY, AND ANY IMPLIED WARRANTY NOT NEGATED 
HEREBY, INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY AND 
FITNESS FOR A PARTICULAR PURPOSE, DO NOT COVER, AND NEITHER TLV, TII NOR 
ITS TLV GROUP COMPANIES WILL IN ANY EVENT BE LIABLE FOR, INCIDENTAL OR 
CONSEQUENTIAL DAMAGES, INCLUDING, BUT NOT LIMITED TO LOST PROFITS, THE 
COST OF DISASSEMBLY AND SHIPMENT OF THE DEFECTIVE PRODUCT, INJURY TO 
OTHER PROPERTY, DAMAGE TO BUYER’S OR THE FIRST END USER’S PRODUCT, 
DAMAGE TO BUYER’S OR THE FIRST END USER’S PROCESSES, LOSS OF USE, OR 
OTHER COMMERCIAL LOSSES. WHERE, DUE TO OPERATION OF LAW, 
CONSEQUENTIAL AND INCIDENTAL DAMAGES UNDER THIS WARRANTY, UNDER ANY 
OTHER EXPRESS WARRANTY NOT NEGATED HEREBY OR UNDER ANY IMPLIED 
WARRANTY NOT NEGATED HEREBY (INCLUDING THE IMPLIED WARRANTIES OF 
MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE) CANNOT BE 
EXCLUDED, SUCH DAMAGES ARE EXPRESSLY LIMITED IN AMOUNT TO THE 
PURCHASE PRICE OF THE DEFECTIVE PRODUCT. THIS EXCLUSION OF 
CONSEQUENTIAL AND INCIDENTAL DAMAGES, AND THE PROVISION OF THIS 
WARRANTY LIMITING REMEDIES HEREUNDER TO REPLACEMENT, ARE 
INDEPENDENT PROVISIONS, AND ANY DETERMINATION THAT THE LIMITATION OF 
REMEDIES FAILS OF ITS ESSENTIAL PURPOSE OR ANY OTHER DETERMINATION 
THAT EITHER OF THE ABOVE REMEDIES IS UNENFORCEABLE, SHALL NOT BE 
CONSTRUED TO MAKE THE OTHER PROVISIONS UNENFORCEABLE. 

Exclusion of Other Warranties 

THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, 
AND ALL OTHER WARRANTIES, INCLUDING BUT NOT LIMITED TO THE IMPLIED 
WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, 
ARE EXPRESSLY DISCLAIMED. 

Severability 

Any provision of this warranty which is invalid, prohibited or unenforceable in any 
jurisdiction shall, as to such jurisdiction, be ineffective to the extent of such invalidity, 
prohibition or unenforceability without invalidating the remaining provisions hereof, 
and any such invalidity, prohibition or unenforceability in any such jurisdiction shall 
not invalidate or render unenforceable such provision in any other jurisdiction.   

Содержание A-DR20-10

Страница 1: ...172 65634MAJ 03 A DR20 6 October 2021 Direct acting Pressure Reducing Valve for Air A DR20 2 A DR20 6 A DR20 10 Copyright 2021 by TLV CO LTD All rights reserved ...

Страница 2: ...of using the product properly The TLV A DR20 is a direct acting pressure reducing valve for air which adopts a soft seat design on the main valve and minimizes the lockup pressure It also provides a more stable secondary pressure than conventional direct acting reducing valves The A DR20 is designed for a long service life and is made of stainless steel for superior durability For products with sp...

Страница 3: ...there is a potential threat of death or serious injury Indicates that there is a possibility of injury or equipment product damage Install properly and DO NOT use this product outside the recommended operating pressure temperature and other specification ranges Improper use may result in such hazards as damage to the product or malfunctions that may lead to serious accidents Local regulations may ...

Страница 4: ...ch may cause burns or other injury Use only under conditions in which no freeze up will occur Freezing may damage the product leading to fluid discharge which may cause burns or other injury Use only under conditions in which no water hammer will occur The impact of water hammer may damage the product leading to fluid discharge which may cause burns or other injury CAUTION ...

Страница 5: ... Refer to the product nameplate for detailed specifications Valve No is displayed for products with options This item is omitted from the nameplate when there are no options Acceptable Operating Range Model A DR20 2 A DR20 6 A DR20 10 Primary Pressure Range 0 2 1 0 MPaG 30 150 psig 0 6 1 0 MPaG 85 150 psig Pressure Adjustable Range 0 014 0 2 MPaG 2 30 psig but limited to 1 30 of primary pressure 0...

Страница 6: ...de 15 Steel Ball 16 Cover Bolt 17 Locknut 18 Adjustment Handle 19 Nameplate 20 Retaining Ring 21 Slide Bearing 3 4 22 Snap Ring 3 4 1 Replacement parts are available only in the following kits A Maintenance Kit B Repair Kit for Spacer C Repair Kit for Main Valve D Repair Kit for Bellows 2 Rubber standard fluorine rubber is used in the seating area The rubber is inlaid in the main valve 3 Number of...

Страница 7: ...arily To save energy install the on off valve as near to the boiler or compressor as possible NOTE To prevent water hammer it is recommended that a slow acting motorized on off valve be used If a fast acting solenoid valve is used the potential water hammer effect can damage the air using equipment and the pressure reducing valve 3 Installing a Control and or Safety Valve A control valve i e for t...

Страница 8: ...al size is 25 mm 1 in have 750 mm 30 in or more Maintain a straight piping run of 30 d or more when another pressure reducing valve is installed Two stage pressure reduction Example if nominal size is 25 mm 1 in have 750 mm 30 in or more 2 Outlet secondary side of the A DR20 Maintain a straight piping run of 15 d or more when a manual valve a strainer or an elbow etc is installed Example if nomina...

Страница 9: ... be sure to blow down all piping thoroughly If this is not possible perform a blowdown using the bypass valve Blowdown is especially important for newly installed piping or after the system has been shut down for a long period of time 2 Removing the Protective Caps Before installation be sure to remove all protective seals and caps covering the product inlet and outlet Found in 2 locations on the ...

Страница 10: ...ating range limitations such as when the reduction ratio is greater than 30 1 8 Accessories Always install a shut off valve pressure gauge and bypass lines at both inlet and outlet Ball valves which will not retain condensate are recommended for inlet and outlet shut off valves The bypass pipe should be at least of the size of the inlet primary pipe A DR20 Open Closed Closed Primary Side Secondary...

Страница 11: ... shutting down the system always close the outlet shut off valve first and then the inlet valve Maintenance Take measures to prevent people from coming into direct contact with product outlets Failure to do so may result in burns or other injury from the discharge of fluids CAUTION Be sure to use only the recommended components when repairing the product and NEVER attempt to modify the product in ...

Страница 12: ...ial run of a new line or before or after equipment is taken out of service for a long period of time Installation inspection maintenance repairs disassembly adjustment and valve opening closing should be carried out only by trained maintenance personnel Remove all pressurized air from the piping both upstream and downstream Remove the A DR20 from the piping and secure it in a vise to perform disas...

Страница 13: ...e rubber is inlaid in the main valve and cannot be removed The main valve itself must be replaced Cleaning After inspection and removal of any abnormality clean and reassemble the parts The following parts will require cleaning before reassembly Threads of the adjustment handle threads of the cover bellows valve stem main valve valve seat spacer including slide bearing screen It is permissible to ...

Страница 14: ...e main valve and cannot be removed The main valve itself must be replaced Valve Seat Valve Seat Gasket Main Valve 3 Coil Spring Screen Body Adjustment Handle Locknut Cover Bolt Cover Retaining Ring Steel Ball Spring Guide Spacer Slide Bearing 1 Slide Bearing 1 Snap Ring 1 Snap Ring 1 Bellows Cover Gasket Snap Ring 2 Valve Stem Coil Spring 2Insert the snap ring so that both ends are facing down ...

Страница 15: ... one at a time in a diagonal pattern alternately to provide uniform seating 4 After assembly make sure that the valve stem operates smoothly without binding As shown in the figures above when the main valve is tightened it may become off centered on the valve seat If this occurs move the main valve back to center 5 Standard torque for fastening the respective screws and the width across flats of t...

Страница 16: ...the Acceptable Operating Range Correct Usage of the A DR20 Direct acting Pressure Reducing Valve and Adjustment sections be reviewed Problem Symptom Cause Remedy The secondary pressure does not rise Pressure does not increase No air is being supplied Check the primary secondary piping and valves of the unit The valve at the primary side is closed The entrance to the screens or strainer is clogged ...

Страница 17: ... too low Check the flow rate check the model selection replace with a unit that has smaller nominal diameter or a more suitable unit if necessary Hunting never stops There is too high a reduction ratio Use two stage reduction The selected model is inappropriate for the service conditions specifications Check the model selection replace with a more suitable unit if necessary Chattering never stops ...

Страница 18: ...beyond the control of TLV TII or TLV group companies or 6 improper storage maintenance or repair or 7 operation of the Products not in accordance with instructions issued with the Products or with accepted industry practices or 8 use for a purpose or in a manner for which the Products were not intended or 9 use of the Products in a manner inconsistent with the Specifications or 10 use of the Produ...

Страница 19: ...ISASSEMBLY AND SHIPMENT OF THE DEFECTIVE PRODUCT INJURY TO OTHER PROPERTY DAMAGE TO BUYER S OR THE FIRST END USER S PRODUCT DAMAGE TO BUYER S OR THE FIRST END USER S PROCESSES LOSS OF USE OR OTHER COMMERCIAL LOSSES WHERE DUE TO OPERATION OF LAW CONSEQUENTIAL AND INCIDENTAL DAMAGES UNDER THIS WARRANTY UNDER ANY OTHER EXPRESS WARRANTY NOT NEGATED HEREBY OR UNDER ANY IMPLIED WARRANTY NOT NEGATED HERE...

Страница 20: ...oad Nunawading Victoria 3131 Australia Tel Fax 61 0 3 9873 5610 61 0 3 9873 5010 In East Asia 36 Kaki Bukit Place 02 01 02 Singapore 416214 Tel Fax 65 6747 4600 65 6742 0345 Room 5406 No 103 Cao Bao Road Shanghai China 200233 Tel Fax 86 0 21 6482 8622 86 0 21 6482 8623 No 16 Jalan MJ14 Taman Industri Meranti Jaya 47120 Puchong Selangor Malaysia Tel Fax 60 3 8065 2928 60 3 8065 2923 252 94 K L 17th...

Отзывы: