![TLC ES42C Скачать руководство пользователя страница 4](http://html1.mh-extra.com/html/tlc/es42c/es42c_user-manual_1121214004.webp)
FIGURE 13
(4) SENS. ADJUSTMENT
The sensitivity adjustment may be adjusted to
compensate for seasonal variations in temperature and
to reduce unwanted triggering. The optimum sensitivity
can be achieved by setting the SENS. control knob
initially to its mid-point and then adjusting the control
knob clockwise to increase (up to 12 meters) the
detecting distance or anti-clockwise to decrease (down
to 3 meters) the detecting distance.
OPERATION
By using the wall switch connected to your motion
sensor floodlight, you can easily select one of two modes
of operation: Automatic Operation and Manual Override.
(1) AUTOMATIC OPERATION
Turn on the wall switch. When the motion sensor detects
motion, the floodlight automatically turns on. The built-in
photocell sensor turns the motion sensor off and on
according to the light level set by the LITE Adjustment.
(1)
MANUAL OVERRIDE
To keep the light on regardless of the motion, you can
override the Automatic Operation. By turning the wall
switch off and on within 2 seconds, the light will remain
on. Users can also set the motion sensor back to
Automatic Operation by turning off the wall switch for at
least 10 seconds and then turn it back on.
TROUBLE SHOOTING
Light does not turn on:
l
Confirm that you have made a correct “wiring
connection”.
l
Make sure that the bulb has not burned out.
Light remains on:
l
Make sure the wiring connection is correct.
l
If you set the motion sensor to Manual Override,
remember that you must turn the wall switch off
for at least 10 seconds before switch the motion
sensor on back to Automatic Operation.
l
Check if the TIME setting is correct.
6
SPECIFICATIONS
Power Requirement
AC 220 ~ 240V / 50Hz
Power Cord Requirement H05RN-F, 3G, 1.0mm²
Lighting Load
Max. 500W Halogen Bulb
Detection Angle
Up to 110
°
at 20
°
C
Detection Distance
Up to 12M at 20
°
C
Swiveling Angle
Lamp Part: Vertical 90°;
Sensor Part: Horizontal 50
°
,
Vertical 40
°
Mounting Height
Recommended 1.8 ~ 2.5M
(5.9 ~ 8.2 Ft) Wall Mount
Wall Switch Control
On / Off / Manual Override
Sensor Operation
Auto
Time Adjustment
5 ± 3 sec ~ 12 ± 3 min
Lux Adjustment
Approx. 0 ~ 1,000 Lux.
Operating Temperature
-20
°
C ~ +40
°
C
Warm Up Time
About 1 min
Protection Class
Class I
Protection Degree
IP44
Safety
CE, GS
INE42CEVSPEC
7