![TLC ES42C Скачать руководство пользователя страница 3](http://html1.mh-extra.com/html/tlc/es42c/es42c_user-manual_1121214003.webp)
FIGURE 9
Note: Do not at this stage re-attach the floodlight to the
bracket.
(3) Remove the cover screws from the wiring box on the
rear of the floodlight. Loosen two screws on the
pressure block and unscrew the waterproof cable
gland.
(4) Route the power cord through the cable gland and
pressure block.
Note: The power cord must meet H05RN-F, 3G, 1.0mm
²
requirement.
(5) Strip approximately 6-8mm insulating part of the
wires from the power cord. Before connection,
ensure that the wiring box gasket is firmly seated in
its original place.
(6) Connect the BROWN wire (Live wire) to the terminal
block “L” mark. Connect the BLUE wire (Neutral wire)
to the terminal block “N” mark. Connect the
YELLOW/GREEN (Ground wire) to the terminal
block “
“ mark (If used, when the power cord has
it)(FIGURE 10)
.
FIGURE 10
(7) Use the pressure block to fix the power cord by
fastening its two screws. Tighten the cable gland
and refit the wiring box cover.
(8) Re-attach the floodlight to the bracket and secure the cable to
the wall using suitable clips. Ensure that the cable is not
touching the body of the floodlight, and that there is sufficient
slack in the cable to allow the floodlight to be tilted and
adjusted as required, which should be done by grasping the
metal body of the floodlight, not its rear wiring box.
4
SETTING THE LIGHTING SYSTEM
(1)
TEST MODE
l
Turn the Lite control and the Time control anti-
clockwise to the edge – the TEST position. Set the
Sens. Control to its mid-point. (FIGURE 11)
FIGURE 11
l
Turn on the wall switch. The floodlight will turn on for
about 1 minute to warm up. Then it turns off. Walk
through the detection area. The floodlight turns on
when you move and turns off when you stop. Wait
for the floodlight to turn off before moving again to
test the sensor.
l
Adjust the motion sensor to cover the desired
detection area. For a smaller coverage area, point
the sensor down; for a larger coverage area, point
the sensor up.
(2) TIME ADJUSTMENT
The TIME adjustment controls how long the floodlight will
stay on after the motion has been detected.
Turn the TIME control knob clockwise to increase (up to
about 12 minutes) how long the floodlights stay on or
anti-clockwise to decrease (down to about 5 seconds)
the time delay (FIGURE 12).
FIGURE 12
(3) LITE ADJUSTMENT
The LITE adjustment determines at what light level the
lighting system will start operating when you set the
sensor to Automatic Operation.
Provisionally turn the LITE control knob to the edge
clockwise at the moon (dusk) position (FIGURE 13). In
this provisional setting mode, the motion sensor remains
inactive during daylight. At dusk when you find it is the
LUX level desired for operation, simply set the LITE
control knob to the position that the motion sensor will
become active as daylight declines.
5