FIGURE 9

 

 Note: Do not at this stage re-attach the floodlight to the

bracket.

 
(3)   Remove the cover screws from the wiring box on the

rear of the floodlight. Loosen two screws on the
pressure block and unscrew the waterproof cable
gland.

(4)   Route the power cord through the cable gland and

pressure block.

 Note: The power cord must meet H05RN-F, 3G, 1.0mm

²

requirement.

 
(5)   Strip approximately 6-8mm insulating part of the

wires from the power cord. Before connection,
ensure that the wiring box gasket is firmly seated in
its original place.

(6)   Connect the BROWN wire (Live wire) to the terminal

block “L” mark. Connect the BLUE wire (Neutral wire)
to the terminal block “N” mark. Connect the
YELLOW/GREEN (Ground wire) to the terminal

block “ 

 “ mark (If used, when the power cord has

it)(FIGURE 10)

.

 

 

 FIGURE 10

 
(7)   Use the pressure block to fix the power cord by

fastening its two screws. Tighten the cable gland
and refit the wiring box cover.

(8)   Re-attach the floodlight to the bracket and secure the cable to

the wall using suitable clips. Ensure that the cable is not
touching the body of the floodlight, and that there is sufficient
slack in the cable to allow the floodlight to be tilted and
adjusted as required, which should be done by grasping the
metal body of the floodlight, not its rear wiring box.

4

SETTING THE LIGHTING SYSTEM

(1)

 

TEST MODE

l

 

Turn the Lite control and the Time control anti-
clockwise to the edge – the TEST position. Set the
Sens. Control to its mid-point. (FIGURE 11)

FIGURE 11

l

 

Turn on the wall switch. The floodlight will turn on for
about 1 minute to warm up. Then it turns off. Walk
through the detection area. The floodlight turns on
when you move and turns off when you stop. Wait
for the floodlight to turn off before moving again to
test the sensor.

l

 

Adjust the motion sensor to cover the desired
detection area. For a smaller coverage area, point
the sensor down; for a larger coverage area, point
the sensor up.

(2) TIME ADJUSTMENT

The TIME adjustment controls how long the floodlight will
stay on after the motion has been detected.

Turn the TIME control knob clockwise to increase (up to
about 12 minutes) how long the floodlights stay on or
anti-clockwise to decrease (down to about 5 seconds)
the time delay (FIGURE 12).

FIGURE 12

(3) LITE ADJUSTMENT

The LITE adjustment determines at what light level the
lighting system will start operating when you set the
sensor to Automatic Operation.

Provisionally turn the LITE control knob to the edge
clockwise at the moon (dusk) position (FIGURE 13). In
this provisional setting mode, the motion sensor remains
inactive during daylight. At dusk when you find it is the
LUX level desired for operation, simply set the LITE
control knob to the position that the motion sensor will
become active as daylight declines.

5

Содержание ES42C

Страница 1: ...vertically FIGURE 1b HORIZONTAL VERTICAL FIGURE 1a 1b IMPORTANT Some local building codes may require installation of this product by a qualified electrician Check your local codes as they apply to your situation If the house wiring is of aluminum consult with an electrician about proper wiring methods Maintenance or repairing work such as replacing current fuse shall be done by a qualified electr...

Страница 2: ...sockets Locate the other end into the other socket FIGURE 5 FIGURE 5 6 Carefully replace front surround making sure that the seal is correctly positioned Screw up tightly FIGURE 6 2 FIGURE 6 INSTALLATION To facilitate installation it is essential to get a drill and a screwdriver ready Select a location for the unit based on the coverage angles shown in FIGURE 7 UNIT M COVERAGEANGLES FIGURE 7 Insta...

Страница 3: ...NGTHELIGHTINGSYSTEM 1 TESTMODE l Turn the Lite control and the Time control anti clockwise to the edge the TEST position Set the Sens Control to its mid point FIGURE 11 FIGURE 11 l Turn on the wall switch The floodlight will turn on for about 1 minute to warm up Then it turns off Walk through the detection area The floodlight turns on when you move and turns off when you stop Wait for the floodlig...

Страница 4: ...econds the light will remain on Users can also set the motion sensor back to Automatic Operation by turning off the wall switch for at least 10 seconds and then turn it back on TROUBLESHOOTING Lightdoesnotturnon l Confirm that you have made a correct wiring connection l Make sure that the bulb has not burned out Lightremainson l Make sure the wiring connection is correct l If you set the motion se...

Отзывы: