background image

 

 

 

 

Page | 11  

 

 TrueLifeAudio

 

WARNINGS AND MAINTENANCE 

The 

SSP-1 Control Preamplifier 

will be warm.  

Due to the vacuum tubes used in the 

TrueLife Audio

 design, it is normal that the unit feels warm. Proper ventilation 

will be needed as described in section preparation for installation. 

Make sure the preamp and power supply is off before making any system connections. Do not remove or 
insert the 6-pin Nutrich  power supply connectors when the power supply mains switch is in the on position. 
 
This unit contains voltages which can cause serious injury or death. Do not operate with cover removed. Refer 
servicing to your authorized 

TrueLife Audio

 dealer or other qualified personnel. 

 

Replacing the Tubes 

Before you take any action, please unplug the power cable of the unit from the mains. After unplugging let at least one 
hour to pass before you proceed with the replacement of the tubes. Let the preamp tube(s) cool down, if necessary, 
before handling. Tube heater filaments are somewhat more suceptable to damage when warm or hot. 

Your 

SSP-1 Control Preamplifier

 uses four tubes in the audio preamplifier unit, two tubes type 6J5G for each 

channel and two rectifier tubes type EZ32, one for each channel in the power supply unit.   

In the case that the tubes need to be replaced, follow the steps in the paragraph bellow.  

Each tube should require only moderate force for removal and replacement. Gently rock the tube back and forth a bit 
during removal or replacement. 
 

Each unit (control amplifier and power supply) have one top cover that actually consists of three pieces but can be 
removed as one panel. In order the top panel to be removed for replacing the tubes, you just have to use an Allen key 
and remove four screws closer to the front plate, then three screws closer to the back plate and finally two more on 
the side panels holding the middle piece. In total nine (9) screws need to be removed.   

Please use only premium quality tubes that you can purchase from the local 

TLA

 dealer or directly from the 

manufacturer.  

Mains 

Unplug your 

SSP-1 Control Preamplifier system 

from the mains connection in the following cases: 

- before you manipulate with cables 

- before you clean your amplifier 

- during thunder storms or 

- before you leave for longer periods  
    

Cleaning  

Please use a soft towel for the cleaning of your Preamplifier. We recommend the use of a nonabrasive micro fiber 
towel. Please do not employ any solvents.  

Security advice 

Liquidity is not allowed to enter the Preamplifier. The electronic may be damaged seriously. 

Packing 

Please keep the original packing for future transports. The original packing is optimal protection against potential 
damages. 

 

Содержание SSP-1

Страница 1: ...Page 1 TrueLifeAudio SSP 1 Stereo Tube Control Preamplifier Owner s Manual...

Страница 2: ...FETY PRECAUTIONS 3 TLA PROFILE INTRODUCTION 4 SSP 1 Preamplifier DESCRIPTION 5 FRONT VIEW 6 BACK VIEW 7 SPECIFICATIONS 8 PREPARATION AND INSTALLATION 9 10 WARNINGS AND MAINTENANCE 11 12 WARRANTY 13 WA...

Страница 3: ...Y THE VOLTAGE INDICATED ON REAR PANEL WARNING Before any maintenance or placement disconnect the device from the electrical outlets WITH THE POWER SWITCH TO OFF DISCONNECT THE DEVICE THE WAY THAT THE...

Страница 4: ...alistic sound When we come with a new product we make it for ourselves first Velissarios says A TLA amplifier starts its life with the innovative circuit it integrates being tested in the lab and opti...

Страница 5: ...t build around two 6j5 tubes The Output Transformers are designed from TLA hand wound with the highest quality materials Shunt type volume attenuator which means the minimum signal deterioration cause...

Страница 6: ...View 1 Mute Switch 2 Logo lights up when power is on 3 Input selector switch 4 Volume attenuator 5 Input selector indication PSU 1 Power Supply Unit Front View 1 Power switch Right channel supply 2 P...

Страница 7: ...level Input Right and Left channels Unbalanced 6 RCA Tuner Line level Inputs Right and Left channels Unbalanced 7 RCA CD Line level Inputs Right and Left channels Unbalanced 8 RCA Phono Line level In...

Страница 8: ...ns Color Options of both units Front Plate Silver Black Both Units Dimensions W x H x D 440 X 192 with feet X445 mm Unit Weight 30 Kg power supply 26 Kg audio unit Both Units Shipping Dimensions W x H...

Страница 9: ...Supply Unit includes two power on off switches Be sure to press on the power switches after you finish with all connections When the left hand side power switch left channel is pressed on the TLA logo...

Страница 10: ...tight on the jack to avoid hum Connecting input cables Three pairs of INPUT RCA connectors and one pair of INPUT XLR connectors are located on the far right side of the rear panel of the preamplifier...

Страница 11: ...the case that the tubes need to be replaced follow the steps in the paragraph bellow Each tube should require only moderate force for removal and replacement Gently rock the tube back and forth a bit...

Страница 12: ...ing charges insurance re importation to your country and duty arrangements When shipping a product to the factory for service always include the following 1 A sales slip or other proof of purchase if...

Страница 13: ...he correct recording of the serial number of the amplifier on your warranty registration card If a TrueLife Audio product fails to meet the above warranty then the purchaser s sole remedy shall be to...

Страница 14: ...to validate your warranty and registration Thank you again for choosing TrueLife Audio MODEL _________________SERIAL No ______________________________________________ PURCHASE DATE ________ SUPPLIER _...

Страница 15: ...Page 15 TrueLifeAudio CONTACT INFORMATION Address Ippokratous 13 Keratsini 18756 Athens Greece Phone 30 210 5757605 Email info truelifeaudio com...

Страница 16: ...Page 16 TrueLifeAudio...

Страница 17: ...Page 17 TrueLifeAudio...

Страница 18: ...Page 18 TrueLifeAudio...

Страница 19: ...Page 19 TrueLifeAudio...

Отзывы: