    XSNet 3100MC 

Installation 

This chapter gives step-by-step installation instructions for the Converter. 
 

Selecting a Site for the Equipment                        

As with any electric device, you should place the equipment where it will 
not be subjected to extreme temperatures, humidity, or electromagnetic 
interference. Specifically, the site you select should meet the following 
requirements: 

 

 

The ambient temperature should be between 32 and 113 degrees Fahrenheit (0 to 45 degrees 

Celsius). 

 

The relative humidity should be less than 95 percent, non-condensing. 

 

Surrounding electrical devices should not exceed the electromagnetic field (RFC) standards for 

IEC 801-3, Level 2 (3V/M) field strength. 

 

Make sure that the equipment receives adequate ventilation. Do not block the ventilation holes 

on each side of the equipment. 

 

The power outlet should be within 1.8 meters of the product.

 

 

Connecting to Power                                              

 This Converter is a plug-and-play device. 

 

 Connect the supplied AC to DC power adaptor to the receptacle on the rear panel of the converter, 

and then attach the plug into a standard AC outlet. 

 

 

 

  

7

 

 
 
 
 

Содержание Siqura XSNet 3100MC

Страница 1: ...10Base T and IEEE802 3u 100Base TX FX standards In this manual you will find Product overview Features on the media converter Illustrative LED functions Installation instructions Specifications Import...

Страница 2: ...CONTENTS 2 INTRODUCTION 3 PRODUCT OVERVIEW 3 PRODUCT FEATURES 3 PACKING LIST 3 ONE CHANNEL MEDIA CONVERTER 4 PORTS 4 PORT SETTINGS 4 LINK FAULT PASS THROUGH 5 INSTALLATION 7 SELECTING A SITE FOR THE...

Страница 3: ...r transmits with 1550nm wavelength and receives with 1310nm wavelength Auto negotiation of speed and duplex mode on TX port Auto MDIX on TX port One DIP switch for configuring link fault pass through...

Страница 4: ...elow for more details DIP switch No Down Up 1 Enable LFPT Disable LFPT LFPT link fault pass through 2 Enable auto negotiation for TX port Enable forced mode for TX port 3 TX port forced to 100Mbps TX...

Страница 5: ...e FDX stands for FULL DUPLEX Flashing Collision occurred COL stands for COLLISION FDX COL Off Connection in half duplex mode Link Fault Pass Through Connect the FX ports of two Media Converters A and...

Страница 6: ...f the FX port TX Port FX Port LEDs PWR 100 LNK ACT FDX COL LNK ACT FDX COL Media Converter A ON OFF OFF OFF OFF OFF Media Converter B ON OFF OFF OFF OFF OFF Link Fault of the TX port of the Media Conv...

Страница 7: ...hrenheit 0 to 45 degrees Celsius The relative humidity should be less than 95 percent non condensing Surrounding electrical devices should not exceed the electromagnetic field RFC standards for IEC 80...

Страница 8: ...uplex Switching Method Store and Forward Forwarding rate 14 880 148 810pps for 10 100Mbps Per Unit 2 LEDs Power 100 Mbps LED Indicators Per Port 2 LEDs LNK ACT FDX COL Dimensions 80 3mm W 109 2mm D 23...