Toggle down Pin 5 to force the FX port at full duplex mode. Or toggle up Pin 5 for half duplex mode.
Toggle up Pin 1 to disable the link-fault-pass-through.
Connect the converter to the power again. The new setting will come into effect then.
LED Indicators
The LED indicators give you instant feedback on status of the converter:
LEDs State
Indication
Steady Power
on
PWR stands for POWER
PWR
Off Power
off
Steady
Connection at the speed of 100Mbps
100 (Mbps)
Off
Connection at the speed of 10Mbps
Steady
A valid network connection established
LNK stands for LINK
Flashing
Transmitting or receiving data
ACT stands for ACTIVITY
LNK/ACT
Off
Neither valid network connection established
nor transmitting/receiving data
Steady
Connection in full-duplex mode
FDX stands for FULL-DUPLEX
Flashing Collision
occurred
COL stands for COLLISION
FDX/COL
Off
Connection in half-duplex mode
Link-Fault-Pass-Through
Connect the FX ports of two Media Converters A and B through the fiber
cable.
Link Fault of the FX port:
A Link Fault condition will be sensed on the TX port whenever the media
converter detects a Link Fault condition on the FX port. Thus, the 100,
LNK/ACT, and FDX/COL LEDs of the media converter would be off.
Link Fault of the TX port of the Media Converter A:
The Media Converter A: A Link Fault condition will be sensed on the FX
port whenever the media converter detects a Link Fault condition on the
TX port. Thus, the 100, LNK/ACT, and FDX/COL LEDs of the TX port of
the Media Converter A would be off.
The Media Converter B: A Link Fault condition will be informed to the FX
port of the Media Converter B. Then a Link Fault condition will be sensed
on the TX port of the Media Converter B whenever the Media Converter B