background image

17 

 

 

Troubleshooting 9421D Links

 

The indicator LEDs on the transmitter and receiver provide information as to the optical and electrical status of 
the units. Troubleshooting normally starts at the transmitting end. 
  
On the 9421DT and 9421DR cards, the sync indicator should be illuminated with one of three colors. If it is 

not

 

illuminated, check the chassis power supply, power source, and connections.  

 

When the SYNC indicator is illuminated 

green

,

 operation is normal. When the SYNC is illuminated 

red

, this is 

usually an indication of insufficient optical signal at the optical input. Check the fiber for poor connections or 
optical losses greater than the unit specifications.  

 

If the SYNC indicator is 

yellow

, the local unit is in sync and the remote unit is not. This usually means that there 

is an optical loss problem in one direction from the local unit to the remote. Again, check the fiber for bends or 
check the optical link for excessive losses.  

 

Since this unit uses two wavelengths, the losses for each one can be different. Each wavelength reacts 
differently to bends and splices as well.  

 

When video is connected to Channel 1 or Channel 2 input BNCs, the Video Present indicator for that channel 
should be illuminated green. If the Video Present indicator is not green, then check the video source and 
connections.  

 

IF both STATUS indicators are illuminated 

green 

and the TX Video Present indicator is not illuminated, the video 

source at the 

transmitter 

end should be checked. 

 

 

 

 

 

 

 

Содержание Optelecom 9000 Series

Страница 1: ...ards For transporting two NTSC or PAL or SECAM video signals two duplex user selectable Option Module port signals and a high speed duplex RS422 data port signal over one optical fiber The video is encoded using a 9 bit uncompressed digital technology combined with the data and transmitted on the fiber digitally UM50319 Manual 9421D Rev D ...

Страница 2: ......

Страница 3: ...External Wiring Information 8 Functional Description 9 9421DT Indicator and Connector Locations 10 9421DR Indicator and Connector Locations 12 Set Up and Operation of the 9421D 14 Typical Application of the 9421D 16 Operation of the 9421D with the Network Management System Software 16 Troubleshooting 9421D Links 17 Specifications for the Model 9421D 18 ...

Страница 4: ...manufacture and intended use of the unit TKH Security Solutions USA assumes no liability for the customer s failure to comply with any of these safety requirements RM 1 LASER RADIATION DO NOT VIEW DIRECTLY WITH OPTICAL INSTRUMENTS MAGNIFIERS CLASS 1M LASER PRODUCT CAUTION DISCONNECTED OPTICAL CONNECTORS MAY EMIT OPTICAL ENERGY DO NOT VIEW BEAM WITH OPTICAL INSTRUMENTS MAGNIFIERS This product conta...

Страница 5: ... estándares de diseño fabricación y el uso destinado a la unidad TKH Security Solutions USA no asume ninguna responsabilidad si el cliente no cumple con alguno de estos reequisitos de seguridad RM 1 RADIACIÓN LÁSER NO VER DIRECTAMENTE CON INSTRUMENTOS ÓPTICOS DE AUMENTO PRODUCTO LÁSER CLASE 1M PRECAUCIÓN LOS CONECTORES ÓPTICOS DESCONECTADOS PUEDEN AMITIR ENERGĺA ÓPTICA NO VER EL HAZ CON INSTRUMENT...

Страница 6: ...ons und Herstellungsstandards und erfolgt im gegensatz zum vorgesehenen Verwendungszweck dieser Einheit TKH Security Solutions USA übernimmt keine Haftung für das Verabsäumnis des Kunden diese Sicherheitsanforderungen einzuhalten RM 1 LASER STRAHLUNG NICHT DIREKT MIT OPTISCHEN INSTRUMENTEN LUPEN ANSEHEN LASER PRODUKT DER KLASSE 1M VORSICHT ABGEKLEMMTE OPTISCHE STECKVERBINDER KÖNNEN OPTISCHE ENERGI...

Страница 7: ...fabrication et indication d usage de l appareil TKH Security Solutions USA n est pas responsable du non respect de ces consignes de sécurité par le client RM 1 RAYONNEMENT LASER NE PAS REGARDER DIRECTEMENT AVEC DES INSTRUMENTS OPTIQUES LOUPES PRODUIT LASER DE CLASSE 1M ATTENTION LES CONNECTEURS OPTIQUES DEBRANCHES PEUVENT EMETTRE UNE ENERGIE OPTIQUE NE PAS REGARDER LE FAISCEAU AVEC DES INSTRUMENTS...

Страница 8: ... fiber across and then push it back This will put the dirt that was cleaned off back on again e Repeat the process on a dry folded tissue 3 When removing fibers always clean them when replacing them no matter how long you had them off 4 When connecting fibers pay attention to the bend radius of the fibers A general rule is to have a 3 inch 8 cm bend radius A bend radius less than 3 inches is an at...

Страница 9: ...ltiplexed together and converted to an optical signal for transmission to the transmitter on the second wavelength The 9421DT and DR support two TKH Security USA Data Audio Option Modules The modules operate bidirectionally The user may select from duplex audio Option Module type A duplex data Option Module type B duplex contact closure Option Module type C or Stereo Audio Option Module type D Ste...

Страница 10: ...synchronized to the remote unit but the remote unit is reporting it has not synchronized to the local unit Green Sync Loop Normal Operation indicates that the local unit has synchronized to the signal from the remote unit and the remote unit is reporting it has synchronized to the local unit 2 OPTICAL CONNECTOR The optical connection is made here 3 CHANNEL 1 AND CHANNEL 2 VIDEO INPUT CONNECTORS Th...

Страница 11: ...r details on connections to the Option Modules 6 AUX I O 2 CONNECTOR This is the connector for Option Module position 2 Refer to the separate Option Module Manual included with your shipment for details on connections to the Option Modules 7 HIGH SPEED PORT CONNECTOR This RJ45 connector provides the clock and data connections for the high speed port ...

Страница 12: ...chronized to the remote unit but the remote unit is reporting it has not synchronized to the local unit Green Sync Loop Normal Operation indicates that the local unit has synchronized to the signal from the remote unit and the remote unit is reporting it has synchronized to the local unit 2 OPTICAL CONNECTOR The optical connection is made here 3 CHANNEL 1 AND CHANNEL 2 VIDEO OUTPUT CONNECTORS Thes...

Страница 13: ...r details on connections to the Option Modules 6 AUX I O 2 CONNECTOR This is the connector for Option Module position 2 Refer to the separate Option Module Manual included with your shipment for details on connections to the Option Modules 7 HIGH SPEED PORT CONNECTOR This RJ45 connector provides the clock and data connections for the high speed port ...

Страница 14: ...r details on changing Option Module types Please refer to the Option Module manual for instructions on setting and connecting the modules HIGH SPEED PORT OPERATION The high speed port is a 16 Mbps simplex synchronous RS422 port The port may be used synchronously at a speed of 16 MB and asynchronously at up to 1 6 Mbps It may be used as an RS422 port or to interface directly with the 9961 C or 9962...

Страница 15: ... 3 TABLE 1 9421DT AND DR HIGH SPEED PORT CONNECTIONS RJ45 Pin Signal Name 1 Tx Data Input 2 Tx Data Input 3 Tx Clock Output 4 Rx Data Output 5 Rx Data Output 6 Tx Clock Output 7 Rx Clock Output 8 Rx Clock Output ...

Страница 16: ...ronometer Value Cumulative Hours of Operation 7 Reset Cycles Cumulative Number of Power Cycles 8 Firmware Revision 9 Channel 1 Video Present on Input BNC Transmitter only 10 Channel 2 Video Present on Input BNC Transmitter only 11 Channel 1 Video Present on Input BNC at Transmitter Receiver only 12 Channel 2 Video Present on Input BNC at Transmitter Receiver only 13 Local Demultiplexer in Sync Syn...

Страница 17: ...reater than the unit specifications If the SYNC indicator is yellow the local unit is in sync and the remote unit is not This usually means that there is an optical loss problem in one direction from the local unit to the remote Again check the fiber for bends or check the optical link for excessive losses Since this unit uses two wavelengths the losses for each one can be different Each wavelengt...

Страница 18: ...m or 1 0 dB km 1310 nm for 62 5 125 fiber and 0 35 db Km loss on 09 125 fiber at 1310 nm or 0 25 dB Km loss on 09 125 fiber at 1550 nm 2Range may be limited by fiber quality and bandwidth VIDEO SPECIFICATIONS Video Sampling Rate Resolution 16 0 Mhz 9 bit Video Input Output Signal NTSC PAL or SECAM 1V p p 75Ω Video Input Output Connector BNC Video Bandwidth 6 5 Mhz 3 0 dB SNR 63 dB Differential Pha...

Страница 19: ...ensions in inches 6 1 H x 0 8 W x 8 6 D ENVIRONMENTAL Operating Temperature 40 C to 74 C Storage Temperature 55 C to 85 C Relative Humidity 0 to 95 noncondensing MECHANICAL MOUNTING AND CONNECTIONS DIMENSIONS ...

Страница 20: ...Gouda The Netherlands Telephone 31 182 592 333 Fax 31 182 592 123 E mail sales nl tkhsecurity com TKH Security Solutions USA 12920 Cloverleaf Center Drive Germantown Maryland 20874 USA Telephone 1 301 444 2200 Toll Free 1 800 293 4237 Fax 1 301 444 2299 E mail sales us tkhsecurity com ...