20
Connector: I
Description
A
kpBus (RS485)
B
kpBus (RS485)
C
GND (digital ground), for data use only.
S
kpSensor
Reader & IO-2
Connector: J
Description
Connector: K Description
C
GND (digital ground)
A4
Monitored input 4
T2
Digital input (Override card reader)
A5
Monitored input 5
LD
Card reader LED operation
A6
Monitored input 6
D0
DO/Data or Digital input
C
GND (digital ground)
D1
D1/Clock or Digital input
H2
High Power output 2
O4
Digital output 4
C
GND (digital ground)
C
GND (digital ground)
O5
Digital output 5
+V
Power feed card reader
O6
Digital output 6
Connector: L Description
PRT2
Communication port
NOTE
the Orion must not be connected directly to the network. Doing so may result in
severe damage to the device, including loss of functions.
6.5
Status LED
With the RGB LED, the current mode of the Orion can be determined at a single glance. The
Orion’s status LED
is described in the below table:
Port D
Colour of the LED
Description
Light blue
Bootloader : Connecting to iProtect <Checking MD5>
Blue
Bootloader : Starting
Blue
Bootloader : Programming firmware (Or violet)
Pink
Bootloader : No valid application to start
Pink
Application : Format SD card
Orange
Application : Checking SD card (initialisation)
Green
Application : Calamity mode
Red
Application : When using no SD card, the LED will flash red if the
device cannot communicate with the network controller.
Red
Application : If the LED displays a solid red light, the Orion has
detected a surge or short circuit. This also means that the Orion is
not communicating with the network controller.
Orange
Application : If the LED displays a solid amber light, the Orion has
detected a surge or short circuit, but is nevertheless
communicating with the network controller.
Green
Application : The LED will display a solid green light when the
Orion is communicating with the network controller and no input
or output anomalies are detected.
Green
Application : If the location buzzer of the Orion is activated, the
green status LED will flash fast.
Содержание KEYPROCESSOR Orion
Страница 1: ...1 Pluto Orion Doc no 01052018 Modular controller line Installation instructions ...
Страница 4: ...4 ...
Страница 57: ...57 14 Technical drawings 14 1 72000310 Pluto Orion setup with network connection and power supply ...
Страница 58: ...58 14 2 72000206 Pluto Orion with Sirius RS485 and IO ...
Страница 59: ...59 14 3 72000202 Pluto Orion with Sirius clock data Wiegand and I O ...
Страница 60: ...60 14 4 72000207 Pluto Orion with IO Sirius Clock data Wiegand and Orbits ...
Страница 61: ...61 14 5 72000304 Pluto with power supply and USB RS232 converter ...
Страница 62: ...62 14 6 72000203 Pluto Orion with kpBus ...
Страница 63: ...63 14 7 72000204 Orion with kpSensor bus ...
Страница 64: ...64 14 8 72000602 Pluto Orion stacked with 8x RS485 Sirius i readers ...
Страница 65: ...65 14 9 72000602 Pluto Orion with clock data or Wiegand readers ...
Страница 66: ...66 14 10 72000602 Pluto Orion with RS485 readers kpBus combi ...
Страница 67: ...67 14 11 72000504 Polyx with kpBus ...