TKH Security | Siqura INT-RJ / -SM / -MM | 

Installation manual v2

 

 

Before you continue 

 

Prior to installation and operation, carefully read all instructions in this manual and 
heed all warnings. 
Unpack this equipment and handle it carefully. If the package appears to be 
damaged, notify the shipper immediately. 
Use the original packaging to transport the unit. Disconnect power supply before 
moving it. In case of returning the equipment, the original packaging must be 
used. 
Any change performed on the unit that is not previously approved by the 
manufacturer will void both the certification and the warranty. 
This equipment has been designed to fit in harsh environments requiring little or 
no maintenance. Suggested inspection interval is 6 months, but extremely harsh 
environments may require more frequent inspection and maintenance checks. On 
each inspection check the O-ring seals and the eventual window wiper blade 
integrity. Replace them if necessary. 
Make sure that the installation surface can support at least four times the weight of 
the unit in normal operating conditions. In case of excessive external stress (e.g. 
vibration, strong winds or impact), the equipment may need additional means of 
protection. 
Clean the surface of product with a damp cotton cloth. 
To maintain the IP rating of the unit, adequate cable glands must be used. The 
unit must be tightly closed when operating. 
Open only the covers pointed out in this installation manual. Other covers should 
be open only by the manufacturer. 
For security reasons, install the unit out of the reach of children. 
For security reasons, do not install the unit in the proximity of water containers and 
never push objects or pour liquids into the unit. The unit can be safely used in 
damp environments or outdoors, as long as the glands or connectors are properly 
sealed. 
After the installation of the unit, the desiccant bag must be placed inside the unit, 
assuring it won't be damaged by rotating and moving parts 

 

All the electrical connections should be realized in a non-explosive atmosphere. 
Before performing any operation, turn off the power. The installation of the unit 
can be performed only by qualified personnel in accordance with the relevant code 
of practice (e.g., EN60079-14) and with all the relevant local and national 
standards including but not limited to the use of special pipes, tapes, sealants, 
cables and glands. 
When leaving the unit unused for long periods, disconnect supply cables. 
Ensure that the unit case is properly earthed, connecting all the earth ground 
studs. Earth cable should be about 10mm longer than the other cables on the 
connector, in such way that it won't be accidentally disconnected if the cable is 
stretched or pulled. 
When a fiber optical cable is used on the equipment it shall be suitably protected 
against mechanical damage. 

 

The camera must be installed so that the risk of impact on the dome is low. 

Содержание INT-MM

Страница 1: ...TKH TKH Security Siqura EX PD24 Installation manual 1 INT RJ SM MM Installation manual ...

Страница 2: ...s We invite you to offer your suggestions and comments by email via info tkhsecurity com Your feedback will help us to further improve our documentation How to contact us If you have any comments or queries concerning any aspect related to the product do not hesitate to contact TKH Security B V Meridiaan 32 2801 DA Gouda Used electrical electronic and stainless steel products should not be mixed w...

Страница 3: ...n manual v2 3 Contents Contents 3 Description 4 Safe Area SA camera housing 4 Hazardous Area Ex camera housing 4 Before you continue 5 Installation of the unit 6 Installation instruction 7 INT RJ INT SM INT MM 7 INT RJ5 INT RJ10 7 INT SM5 INT SM10 8 ...

Страница 4: ...le with an external cable tail Hazardous Area Ex camera housing The Atex or EX camera housings require a pre installed cable tail The INT RJ5 or INT RJ10 define a EX cable tail for 100 Mb Fast Ethernet of 5 or 10 meter INT SM5 or INT SM10 defines a single mode connection with a 5 or 10 meter multicable and INT MM similar for multi mode The cable is terminated by two Ex d barrier glands on both sid...

Страница 5: ... must be tightly closed when operating Open only the covers pointed out in this installation manual Other covers should be open only by the manufacturer For security reasons install the unit out of the reach of children For security reasons do not install the unit in the proximity of water containers and never push objects or pour liquids into the unit The unit can be safely used in damp environme...

Страница 6: ...ed fuse T Time delay of at least 4 A or fuse of 10 A max Or equivalent resettable devices such as magnetothermal fuses These ratings include inrush current for startup or temporary overload It must be very quickly recognizable and readily accessible For connection to the 24Vac use a multipolar cable having minimum 3x1 5 mm2 15 AWG The mains cable must be protected An all pole mains switch with an ...

Страница 7: ...curity Siqura EX PD24 Installation manual 7 Installation instruction INT RJ INT SM INT MM The interfaces are located in the camera Refer to the camera s installation manual for more information Cable glands and cable are not included INT RJ5 INT RJ10 ...

Страница 8: ...ected 5 2x 50 m 125 m OM2 Not terminated Spare fibers The two unterminated SM fibers can be used as spare if one of the originals breaks or gets serious damaged Inside the camera and at the end of the cable the spare pigtails have 30 cm to 50 cm slack respectively When one of the original fibers are damaged specialized and trained personnel can terminate the cable with the SC optical fiber connect...

Страница 9: ...lation manual 9 INT MM5 INT MM10 1 3x 1 5mm2 Black1 N Black2 L Yellow green PE 2 4x 2x 0 53 mm Cat 6A F UTP Black Not Connected 3 2x 2x 0 22 mm FTP a Grey jacket Washer control 24Vac b Black jacket Not connected 4 4x 9 m 125 m OS1 Not connected 5 2x 50 m 125 m OM2 Terminated with SC ...

Страница 10: ...TKH Security Proposal RFP Name RFP Number TKH Security Siqura INT RJ INT SM Installation manual 10 Our Brands 2020 TKH Security tkhsecurity com 2021 TKH Security B V Our Brands ...

Отзывы: