TKB TZ68-E Скачать руководство пользователя страница 2

6. Remote controls send signals to static controllers to trigger scenes or other actions
7. Remote controls control other actuators.

There are two different role a controller can have. There is always one single primary controller that is managing the 

network and including/excluding devices. The controller may have other functions - like control buttons - as well. All other 

controllers don't manage the network itself but can control other devices. They are called secondary controllers. The 

image also shows that its not possible to operate a sensor just from a remote control. Sensors only communicate with 

static controllers.

Product description

The TKB TZ68 is a switch plug that can be placed between a schuko wall outlet and electric devices, 

plugged in by cord. It can switch all loads up to 3500 W. The device is IP 20 rated and can therefore only be 

used in dry environments. Switching is controlled wirelessly using Z-Wave or locally applying a button. A 

blue LED indicates the switching status.

Before Device is installed

Please read carefully the enclosed user manual before installation of the radio-actuator, in order to ensure 

an error-free functioning.

ATTENTION: only authorized technicians under consideration of the country-specific installation 

guidelines/norms may do works with 230?Volt mains power. Prior to the assembly of the product, the 

voltage network has to be switched off and ensured against re-switching.

The product is permitted only for proper use as specified in the user manual. Any kind of guarantee claim 

has to be forfeited if changes, modifications or painting are undertaken. The product must be checked for 

damages immediately after unpacking. In the case of damages, the product must not be operated in any 

case. If a danger-free operation of the equipment cannot be assured, the voltage supply has to be 

interrupted immediately and the equipment has to be protected from unintended operation.

Installation Guidelines

The Switch Plug can be plugged into every wall outlet for Plug-Type G Britisch Standard. It is IP20 rated and 

can therefore only be used in dry environments. Do not locate the device facing direct sunlight, humid or 

dusty place. The suitable ambient temperature for the device is 0°C ~ 40°C.

Behavior within the Z-Wave network

I

 On factory default the device does not belong to any Z-Wave network. The device needs to join an 

existing wireless network to communicate with the devices of this network. This process is called Inclusion

Devices can also leave a network. This process is called Exclusion. Both processes are initiated by the 

primary controller of the Z-Wave network. This controller will be turned into exclusion respective inclusion 

mode. Please refer to your primary controllers manual on how to turn your controller into inclusion or 

exclusion mode. Only if the primary controller is in inclusion or exclusion mode, this device can join or leave 

(c) 2012 Z-Wave Europe GmbH, Goldbachstr. 13, 09337 Hohenstein-Ernstthal, Germany, All rights reserved, www.zwaveeurope.com - pp 2 

Содержание TZ68-E

Страница 1: ...odes meshed network in case the receiver is not in direct wireless range of the transmitter Z Wave differentiates between Controllers and Slaves Slaves are either sensors S transmitting metered or measured data or actuators A capable to execute an action Controllers are either static mains powered controllers C also referred to as gateways or mobile battery operated remote controls R This results ...

Страница 2: ...st re switching The product is permitted only for proper use as specified in the user manual Any kind of guarantee claim has to be forfeited if changes modifications or painting are undertaken The product must be checked for damages immediately after unpacking In the case of damages the product must not be operated in any case If a danger free operation of the equipment cannot be assured the volta...

Страница 3: ...r inclusion however certain configuration can adapt the function better to user needs or unlock further enhanced features IMPORTANT Controllers may only allow to configure signed values In order to set values in the range 128 255 the value sent in the application shall be the desired value minus 256 For example to set a parameter to 200 it may be needed to set a value of 200 minus 256 minus 56 In ...

Страница 4: ...s can be sensors actuators and even remote controls Primary Controller is the central organizer of the network It must be a controller There can be only one primary controller in a Z Wave network Inclusion is the process of bringing new Z Wave devices into a network Exclusion is the process of removing Z Wave devices from the network Association is a control relationship between a controlling devi...

Страница 5: ...tion regarding the collection systems available If electrical appliances are disposed of in landfills or dumps hazardous substances can leak into the groundwater and get into the food chain damaging your health and well being c 2012 Z Wave Europe GmbH Goldbachstr 13 09337 Hohenstein Ernstthal Germany All rights reserved www zwaveeurope com pp 5 ...

Отзывы: