background image

2

CAUTIONS

WARNING: 

Failure to install, maintain and/or operate the X

CHANGE

R

TM

in accordance with manufacturer’s instructions may result in 

conditions that can produce bodily injury and property damage.

Disconnect power supply to fans and/or control when reversing fan direction or servicing the X

CHANGE

R

TM

. Failure to do so may 

result in personal injury and/or equipment damage.

Make certain the power source is adequate for the X

CHANGE

R

TM

requirements. Do not add the X

CHANGE

R

TM

to a circuit where the 

total electrical load is unknown.

XCHANGER DEHUMIDISTAT CONTROL MODULE OPERATION 

The X

CHANGE

R

TM

control module includes an adjustable dehumidistat control which activates the fan(s) if 

the relative humidity rises above the selected set-point. It is generally recommended to maintain a Relative
Humidity (RH) below 60% to inhibit mold growth. The dehumidistat can be turned fully clockwise to the ‘on’
position for constant fan(s) operation or it can be turned fully counter-clockwise to ‘off’ during seasons or times
when it is not desired for the X

CHANGE

R

TM

fan(s) to run. Each fan can be independently turned on/off by its fan

switch on control module.

STANDARD PLUG-IN TIMER OPERATION

A standard adjustable timer can also be utilized for timed operation of the X

CHANGE

R

TM

fan(s). Plug timer into

standard outlet and plug X

CHANGE

R

TM

control module into wall timer. Turn dehumidistat control fully clockwise

to the ‘on’ position. Both outlets in X

CHANGE

R

TM

control module will be controlled by the wall timer. Each fan

can be independently turned on/off by its fan switch on dehumidistat control module. You can also allow the
dehumidistat control to turn the X

CHANGE

R

TM

on during certain times of the day if you use a timer and keep the

dehumidistat control at the desired set-point.

TJERNLUND OPTIONAL SCP SPEED CONTROL OPERATION

Tjernlund’s optional SCP speed control can be used to vary the speed of both X

CHANGE

R

TM

fans. Plug SCP

speed control into standard outlet and plug X

CHANGE

R

TM

control module into SCP speed control. Both outlets in

X

CHANGE

R

TM

control module will be controlled by the SCP speed control. Each fan can be independently

turned on/off by its fan switch on dehumidistat control module.

RECOMMENDED PATTERNS OF OPERATION

The X

CHANGE

R

TM

X2D model includes a dehumidistat control which can cycle the X

CHANGE

R

TM

fan(s) automatically based on the rel-

ative humidity level of the house or it can be operated based on recommendations below. It is generally recommended to maintain a
Relative Humidity (RH) below 60% to inhibit mold growth.

A standard plug-in wall timer can be programmed based on the lifestyle or needs of the occupants. For example, a family with smok-
ers may want to cycle the X

CHANGE

R

TM

more frequently than a family of non-smokers.

Another timed method may be to cycle the X

CHANGE

R

TM

during peak usage of exhaust fans, such as bathroom, kitchen, laundry or

utility. Outdoor air should be brought in at these peak times to help balance out pressure inside the house.

The X

CHANGE

R

TM

can be cycled on and off at regular intervals to periodically provide fresh air to the home, exhaust stale air or have

one fan bring air in and the other fan exhaust air for a balanced air exchange. It can also be ran like an economizer to bring outside
air in during evening time when it is cooler outside.

HYPOTHETICAL XCHANGER OPERATION BASED ON LIFESTYLE

The example below shows a possible way in which cycling times of the X

CHANGE

R

TM

may be determined based on household 

occupant lifestyles.

6:00 A.M. to 9:00 A.M.

= Outside fresh air should be brought into the house to compensate for morning routines. Bathing, cooking,

laundry and other activities such as smoking necessitate that outside fresh air to be brought in. Depressurization of the house at these
times is common with many exhaust fans running at one time.

9:00 A.M. to 4:00 P.M.

= House is normally vacant with occupants at work or school. Cycle X

CHANGE

R

TM

on and off for 15 minute

intervals per hour to assure fresh air is supplied to the house.

4:00 P.M. to 8:00 P.M.

= Outside fresh air should be brought into the house to compensate for evening routines. Bathing, cooking,

laundry and other activities such as smoking necessitate that outside fresh air to be brought in. Depressurization of the house at these
times is common with many exhaust fans running at one time.

8:00 P.M. to 6:00 A.M.

= All members of the household are usually present. Outside fresh air is needed to dilute occupant generated

carbon dioxide during sleeping. Cycle X

CHANGE

R

TM

on and off for 15 minute intervals, with occasional 30 minute intervals to assure

fresh air is supplied to house.

Содержание XCHANGER X2D

Страница 1: ...rights reserved P N 8504164 THIS DEVICE MUST BE INSTALLED BY A QUALIFIED PERSON READ INSTRUCTIONS CAREFULLY PRIOR TO INSTALLATION AND OPERATION OF THE XCHANGER REV A 05 10 TJERNLUND PRODUCTS INC 1601 Ninth Street White Bear Lake MN 55110 6794 PHONE 800 255 4208 651 426 2993 FAX 651 426 9547 Visit our web site www tjernlund com ...

Страница 2: ... SPECIFICATIONS GENERAL INFORMATION Each XCHANGERTM is electrically factory line tested before shipment After opening carton Inspect thoroughly for hidden damage INSTALLATION RESTRICTIONS WARNING Improper installation adjustment alterations service or maintenance can cause injury or property damage Refer to this manual For assistance or additional information consult a qualified installer service ...

Страница 3: ...ENDED PATTERNS OF OPERATION The XCHANGERTM X2D model includes a dehumidistat control which can cycle the XCHANGERTM fan s automatically based on the rel ative humidity level of the house or it can be operated based on recommendations below It is generally recommended to maintain a Relative Humidity RH below 60 to inhibit mold growth A standard plug in wall timer can be programmed based on the life...

Страница 4: ...Do not exhaust air from mechanical room unless makeup air is also supplied or equipment in mechanical room is sealed combustion Carbon monoxide poisoning may result Use the DT2 6 6 duct take off kit so exhaust can be removed from outside the mechanical room if necessary It is required that the XCHANGERTM be installed in a location where it will not be directed at the occupants Do not discharge int...

Страница 5: ...g ensuring XCHANGERTM will be level 2 CAUTION When cutting or drilling into wall do not damage electrical wiring and other hidden utilities Using a 1 2 bit drill pilot holes noted on the template from inside through rim joist wall board siding etc keeping drill bit perpendicular to the wall 1 2 bit must be long enough to penetrate through exterior 3 Use a level to mark 4 holes drilled in step 2 an...

Страница 6: ... see Diagram K 10 Insert plastic nut into XCHANGERTM base Assemble mounting bracket as shown See Diagram M Attach assembled bracket to bottom of XCHANGERTM Mark bracket mounting location on wall with a slight upward pitch in rear of XCHANGERTM and connect to wall using provided wall anchor See Diagram L 5 DIAGRAM F DIAGRAM E DIAGRAM G INSERT 6 PUSH CLIPS THROUGH EMBOSSED HOLES OF HOUSING CLIPS MUS...

Страница 7: ...side outlets IMPORTANT Do not plug other devices into dehumidistat control or damage may result Once fans are installed in XCHANGERTM plug dehumidistat control into standard outlet The XCHANGERTM control module includes an adjustable dehumidistat control which activates the fan s if the relative humidity rises above the selected set point It is gener ally recommended to maintain a Relative Humidit...

Страница 8: ... was taken from Credit or replacement will only be issued to a Tjernlund distributor after the defective part has been returned prepaid to Tjernlund WHAT IS NOT COVERED Product installed contrary to our installation instructions Product that has been altered neglected or misused Any freight charges related to the return of the defective part Any labor charges related to evaluating and replacing th...

Отзывы: