background image

9

LIMITED PARTS WARRANTY AND CLAIM PROCEDURE

Tjernlund Products, Inc. warrants the components of its products for one year from date of installation.  This warranty covers defects
in material and workmanship.  This warranty does not cover normal maintenance, transportation or installation charges for replace-
ment parts or any other service calls or repairs.  Products that are tampered with, damaged, or defective due to malfunctioning appli-
ances are not covered under this warranty.  This warranty DOES NOT cover the complete Power Venter if it is operative, except for
the defective part.

Tjernlund Products, Inc. will issue credit to the original distributor or provide a free part to replace one that becomes defective during the
one year warranty period.  If the part is over 18 months old, proof of date of the installation in the form of the contractor sales/installa-
tion receipt is necessary to prove the unit has been in service for under one year.  All receipts should include the date code of the Power
Venter to ensure that the defective component corresponds with the complete unit.  This will help preclude possible credit refusal.

1.) Determine defective component.  If unable to determine faulty component, contact your Tjernlund distributor or Tjernlund Products

Technical Customer Service Department at 1-800-255-4208 for troubleshooting assistance.

2.) After the faulty component is determined, return it to your Tjernlund distributor for replacement.  Please include Power Venter date

code component was taken from.  The date code is located on the Electrical Box cover plate.  If Power Venter date code is older 
than 18 months you will need to provide a copy of the original installation receipt to your distributor.  Credit or replacement will only
be issued to a Tjernlund distributor after the defective part has been returned prepaid to Tjernlund.

COVERED PARTS

Motor

Proving Switch

Relays

Wheel

Housing

WHAT IS NOT COVERED

Product installed contrary to our installation instructions
Product that has been altered, neglected or misused
Product that has been wired incorrectly
Product that has been damaged by a malfunctioning or mistuned burner
Any freight charges related to the return of the defective part
Any labor charges related to evaluating and replacing the defective part

REPLACEMENT PARTS

TJERNLUND LIMITED ONE YEAR WARRANTY

Tjernlund Products, Inc. warrants to the original purchaser of this product that the product will be free from defects due to faulty material or workmanship for a
period of (1) year from the date of original purchase or delivery to the original purchaser, whichever is earlier.  Remedies under this warranty are limited to
repairing or replacing, at our option, any product which shall, within the above stated warranty period, be returned to Tjernlund Products, Inc. at the address
listed below, postage prepaid.  THERE ARE NO WARRANTIES WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF, AND TJERNLUND
PRODUCTS, INC. EXPRESSLY DISCLAIMS LIABILITY FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES ARISING FROM THE USE OF THIS PROD-
UCT.  THIS WARRANTY IS IN LIEU OF ALL OTHER EXPRESS WARRANTIES AND NO AGENT IS AUTHORIZED TO ASSUME FOR US ANY LIABILITY
ADDITIONAL TO THOSE SET FORTH IN THIS LIMITED WARRANTY.  IMPLIED WARRANTIES ARE LIMITED TO THE STATED DURATION OF THIS LIM-
ITED WARRANTY.  Some states do not allow limitation on how long an implied warranty lasts, so that limitation may not apply to you.  In addition, some states
do not allow the exclusion or limitation of incidental or consequential damages, so that above limitation or exclusion may not apply to you.  This warranty gives
you specific legal rights and you may also have other rights which may vary from State to State.  Send all inquiries regarding warranty work to Tjernlund
Products, Inc. 1601 9th Street, White Bear Lake, MN 55110-6794.  Phone (612) 426-2993 • (800) 255-4208 • Fax (612) 426-9547.

MODEL HS-3C

MOTOR KIT

950-1022

WHEEL KIT

950-1013

FAN PROVER KIT

950-1032

HOUSING

950-1014

ISOLATION OR

950-1040 

MOTOR RELAY

Содержание HS-3C CANADIAN 8504002 REV 2 0997

Страница 1: ... THIS UNIT READ THESE INSTRUCTIONS THOROUGHLY BEFORE ATTEMPTING INSTALLATION OR OPERATION FAILURE TO FOLLOW THESE INSTRUCTIONS MAY RESULT IN IMPROPER INSTALLATION ADJUST MENT SERVICE OR MAINTENANCE POSSIBLY RESULTING IN FIRE ELECTRI CAL SHOCK CARBON MONOXIDE POISONING EXPLOSION PERSONAL INJURY OR PROPERTY DAMAGE DO NOT DESTROY PLEASE READ CAREFULLY AND KEEP IN A SAFE PLACE ON JOB SITE FOR FUTURE R...

Страница 2: ...ction should occur SPECIFICATIONS CAPACITY The installer must verify that the Power Venter is sized properly using the capacity table to the right The installer may reduce the vent pipe diameter to the size shown in the selection table immediately after the draft hood draft diverter or barometric draft control The vent pipe length shown includes all equivalent vent pipe before and after the Power ...

Страница 3: ...diverter or barometric draft control 5 The Power Venter shall not be installed where the flue gas temperature exceeds 285oC 550o F at the Power Venter inlet Flue gas temperature verification A Consult appliance manufacturer for flue gas temperature after dilution by the draft hood draft diverter or barometric draft control B Measure flue gas temperature at the Power Venter inlet after installation...

Страница 4: ... A venting system shall not direct flue gases towards brickwork siding or other construction in such a manner that may cause damage from heat or condensate from the flue gases A vent system shall not direct flue gases so as to jeopardize people overheat combustible structures or enter buildings A venting system shall not terminate within 1 8 m 6ft of the following A window door or mechanical air s...

Страница 5: ...appropri ate type of vent pipe to the inlet of the Power Venter The vent pipe chosen must be in compliance with local codes The Power Venter inlet and outlet are designed to accept single wall vent pipe If using vent pipe other than single wall the installer must supply adapters to connect to the Power Venter While it is recommended that the Power Venter be mounted at the point of termination it i...

Страница 6: ...at is on the exterior of the housing DO NOT trim the sensing tube portion that will be mounted in the interior of the housing No attempts should be made to substitute the specified materials See Fan Proving Switch installation diagram WIRING All wiring from the Power Venter to the appliance must be in compliance with the local codes or in their absence The Canadian Electrical Code CSA Std C22 1 Al...

Страница 7: ...he installer needs to complete 3 steps to wire the Power Venter as noted below 1 Route the metal conduit from the electrical box to the Power Venter motor and connect the Black White and Ground wires to the motor 2 Connect the Red Blue and Orange wires in the electrical box to the appliance 3 Supply 115 VAC to the input wires in the electrical box NOTE The HS 3C as viewed from the opposite end of ...

Страница 8: ...HS 3C Power Venter is interlocked to 24V controlled appliances Variations of these diagrams are acceptable as long as the Fan Proving Switch isolation circuit is wired to disable the gas valve if a venting mal function should occur 7 HS 3C CONNECTED TO APPLIANCE WITH SPARK IGNITION HS 3C CONNECTED TO A BOILER ...

Страница 9: ...ometric draft control and the appliance flue outlet 2 Make necessary draft adjustments with the barometric draft control appliance burner air intake and the damper located on the outlet of the Power Venter until the appliance manufacturer s recommended draft is present SAFETY INTERLOCK TEST 1 Adjust the appliance thermostat s or aquastat s to call for heat 2 Determine that the Power Venter operate...

Страница 10: ...Housing WHAT IS NOT COVERED Product installed contrary to our installation instructions Product that has been altered neglected or misused Product that has been wired incorrectly Product that has been damaged by a malfunctioning or mistuned burner Any freight charges related to the return of the defective part Any labor charges related to evaluating and replacing the defective part REPLACEMENT PAR...

Отзывы: