Quality engineered and 
manufactured to maintain a
consistent draft on a wide
range of oil and gas fired 
heating equipment. May be
used with chimney vented or
power vented heating equip-
ment. For fan assisted gas, oil
or solid fuel applications with
vent diameters from 4"–10",
choose the DC4 thru DC10. 
For LP and natural gas appli-

cations with vent diameters from 4"–10", choose the DC4G
thru DC10G.

Used with any UC1 con-
trolled Inducer to inter-
lock additional 24/115
VAC heaters.  Powered by
and communicates with
the UC1 through a factory
wired whip.  For one
additional 24/115 VAC
heater add the MAC1E.
To interlock up to four
more additional 24/115
VAC heaters, add the
MAC4E.  MAC4Es can be

daisy chained together for greater than 5 heaters. Important:
Total combined BTU/hr. input of all heaters and total equivalent
pipe lengths must be within Inducer’s capacity.

For use with UC1 Universal
Control, MAC1E or MAC4E 
auxiliary controls.  The WHKE 
gas pressure switch actuates
the Inducer through the A - B
dry contacts.  The Linear Limit
switch disables the heater in
the event of a venting 
malfunction.  Includes JA1
thermocouple junction
adapter. To interlock millivolt
water heater(s) only with a
UC1 controlled Inducer add a

WHKE for each millivolt heater. To interlock a millivolt water
heater and one 24/115 VAC furnace or boiler with a UC1 
controlled Inducer, add a WHKE and a MAC1E.

Solid state control interlocks 
with virtually any burner control 
circuit. Features include:
adjustable pre and post purge,
LED status/diagnostic indicators,
prover switch delay to avoid
burner start up and wind
induced short cycling. Interlocks
with any 24/115 VAC burner 
control circuit and also includes
“dry” contact actuation option.
Selectable voltage eliminates
false activation by burner control
check circuits.

Universal Control  

Model UC1

Millivolt Safety Interlock Kit 

Model WHKE

Barometric Draft Controls

Models DC4, DC5, DC6, DC7, DC8, DC9, DC10 

DC4G, DC6G, DC7G, DC8G, DC9G, DC10G

Multiple Appliance Controls 

Models MAC1E, MAC4E

www.tjernlund.com   •   800.255.4208

For additional information request brochure #8500004

For additional information request brochure #8500490

Accessories

The UC1 is a standardized control for Tjernlund Inducers/Venters.
It offers many installation, operational and safety benefits. 

Model Dimensions

Model

DJ-3

D-3

I

IL

XL

HD

H

7 1/2

9 1/8

14 1/2

17

18 7/8

27 1/2

W

8 1/2

9 1/2

13 1/2

14 3/4

18 1/2

16 3/4

D

5 7/8

7

8 3/4

10

10 1/2

25

X

2 5/8

3 1/8

4

4 1/8

5 1/8

6

Unit

Dimensions (In.)

Slot 

Y

7 5/8

8 5/8

12 3/4

15

16 3/4

24 1/2

Ship

Weight

8 Lbs

10 Lbs

31 Lbs

34 Lbs

53 Lbs

176 Lbs

“H” — Overall Height
“D” — Overall Depth
“W”— Overall Width
“X” — Pipe Slot Width
“Y” — Pipe Slot Height