background image

SAFETY

This pump was designed for specific applications. DO NOT attempt to modify the unit in any way or use it for
any application that it was not designed to do. Ask the dealer or contact the factory if you have any questions
concerning the pump’s application. If factory settings are altered or the application is misapplied, the warranty is
void.
Warnings and cautions in this manual and on decals and tags on the unit are not all inclusive. It would be
impossible to anticipate every circumstance that might involve a hazard. Handling, operating, or servic-
ing this unit by any procedure not recommended by the manufacturer may render this equipment unsafe
and may pose a threat to you or to others.

CAUTION! The engine exhaust contains chemicals
known to the State of California to cause cancer,
birth defects, or other reproductive harm.

Do not operate the pump without water. Per-
manent damage will occur to the ceramic seals
and impellor.

This pump is designed to handle nonvolatile,
nonflammable liquids containing specified en-
trained solids and non-corrosive liquids.

Never attempt to pump volatile, flammable, or
corrosive liquids. This could cause damage to
the pump and its operator(s).

Make certain that all hose connections and pip-
ing are secure and properly supported before
operation.

Do not operate the pump for extended periods
of time with the discharge valve closed. It will
cause pump parts to deteriorate, and may
cause explosion due to high internal pressure
and heat. It can also cause damage to the
pumps ceramic seals

Do not remove covers, plates, gauges, pipe
plugs or fittings from an overheated pump. In-
ternal pressure could cause the parts to be
ejected at high velocities. Allow the pump to
completely cool before servicing.
If over heating occurs:

1.

Stop pump immediately

2.

Ventilate the area

3.

Allow the pump to cool com-
pletely

4.

Check the temperature before
opening any covers, plates,
plugs, or gauges.

5.

Vent pump slowly and cautiously

6.

Refer to manual before restart-
ing pump

Do not operate internal combustion engine in
an explosive atmosphere.

Only operate this unit outside with adequate venti-
lation. This pump’s gas engine exhaust produces
carbon monoxide gas that can cause unconscious-
ness and death.

Operate this equipment at a true horizontial posi-
tion.

Never store pump with fuel in the tank where gas
fuel vapors could be ignited by a flame, spark, or
pilot light from an appliance such as a furnace, water
heater, or clothes dryer.

Never tamper with the governor to gain more
power. The maximum continuous pump speed of
3500 RPM is set at the factory and / not be exceeded
or altered.

Never insert any object through the cooling slots
of the engine. You will damage the unit or cause
injury.

Never refuel a hot or running engine. Avoid over-
filling the fuel tank. Always use the correct type of
fuel. Leave 1/2” between top of fuel and bottom of
tank neck.

This pump was designed for specific applications.
DO NOT attempt to modify the unit in any way or
use it for any application that it was not designed to
do. Ask the dealer or contact the factory if you have
any questions concerning the pumps application.

Warnings and cautions in this manual and on de-
cals and tags on the unit are not all inclusive. It
would be impossible to anticipate every circum-
stance that might involve a hazard. Handling, op-
erating, or servicing this unit by any other proce
-dure not mentioned will void the warranty.

3

Содержание TTP-300

Страница 1: ...on Agency WARNING Do Not Operate Equipment until reading understanding Owner s Manual OWNER S MANUAL MODEL TTP 300 3X3 Commercial Trash Pump P O Box 791 Travelers Rest S C 29690 Phone 864 834 7212 Service Replacement Parts 800 845 4141 Revision 030321A TTP300 Titan Motor Manual WWW TITANINDUSTRIAL NET ...

Страница 2: ...t 1 800 845 4141 with any questions FOR OUTDOOR USE ONLY Never use this unit inside any enclosure including or inside any building No modifications will eliminate the dan ger of possible carbon monoxide poisoning fire or explosion IMPORTANT READ FIRST It is extremely important to read and understand the entire contents of this Owner s Manual for the Titan Industrial Model TTP300 before attempting ...

Страница 3: ...ed pump In ternal pressure could cause the parts to be ejected at high velocities Allow the pump to completely cool before servicing If over heating occurs 1 Stop pump immediately 2 Ventilate the area 3 Allow the pump to cool com pletely 4 Check the temperature before opening any covers plates plugs or gauges 5 Vent pump slowly and cautiously 6 Refer to manual before restart ing pump Do not operat...

Страница 4: ...whichincreasefrictionloss Do not reducethe discharge hole toinduce water pressure Before tightening a connection flange align it exactly with the pump port Never align the hose by tightening the flange bolts Lines near the pump must be independently supported to minimize strain on the pump Pump strain can lead to a decreased pump life Toavoidairpockets whenpriming thesuction line must be as short ...

Страница 5: ...equirenomorethan2minutesfortheinitial prime Ifthepumpdoes not primewithinfivemin utes shut off the engine andtrouble shoot The suction hose should be a minimum of 8 feet long and have a wire filter screen to prevent hard solidobjectsfrom enteringthepumpanddamaging theimpellorandseals Primingisindicatedbyquieteroperation The pumpmaynotprimeimmediatelybecausethe suctionlinemustfirstfillwithliquid If...

Страница 6: ...6 ...

Страница 7: ...7 ...

Страница 8: ...Drain the used oil while the engine is warm Warm oil drains quickly and completely 1 Place a suitable container below the engine to catch the used oil then remove the filler cap dip stick drain plug and washer 2 Allow the used oil to drain completely then reinstall the drain plug washer and tighten drain plug securely 3 Please dispose of used motor oil in a manner that is compatible with the envir...

Страница 9: ...9 ...

Страница 10: ...compression 1 Dirty air filter TROUBLESHOOTING Problem Cause Solution 1 Add liquid to casing 2 Clean or replace 3 Correct leak 4 Replace Suction hose 5 Check pump vacuum replace seal or gasket 6 Check engine 7 Clean strainer 8 Measure lift with vacuum gauge Reduce lift or friction losses in suction line 1 Turn On Off Switch to ON 2 Clean air filter 3 Fill fuel tank 4 Drain fuel tank and refill 5 R...

Страница 11: ...13 11 ...

Страница 12: ...12 ...

Страница 13: ...13 ...

Страница 14: ...ns Ignition System Pull Start Dimensions inches L 36 W 21 1 2 H 25 Net Weight 84 LBS Warranty 1 Year Engine Titan Industrial Commercial 3 X 3 Trash Pump TTP 300 Gallons per hour 15840gph TITAN INDUSTRIAL P O BOX 791 TRAVELERS REST SC 29690 PHONE 864 834 7212 WWW TITANINDUSTRIAL NET ...

Отзывы: