Engine is running but no
power output is available.

Engine runs good until loads
are connected, then bogs
down.

Engine will not start or engine
starts but runs rough.

Engine shuts down during
operation.

Engine lacks power

1. Circuit breaker is open.
2. Poor connection or defective

cord set.

3. Connected device is bad.
4. Fault in generator.

1. Short circuit in a connected

load.

2. Overloaded generator.
3. Engine speed is too slow.
4. Short in generator circuit.

1. On/Off Switch is turned ‘OFF’.
2. Battery is dead
3. Dirty air cleaner.
4. Not enough speed or force is

used for recoil start.

5. Water in fuel.
6. Speed control is not set to

“RUN”.

7. Low oil level.

  8. Engine has lost compression.

1. Out of  fuel.
2. Low oil level.
3. Fault in engine.

1. Load is too high.
2. Dirty air filter.
3. Engine needs to be serviced.

TROUBLESHOOTING

Problem

 Cause

  Solution

1. Reset the circuit breaker.
2. Check & repair.
3. Connect another device

that is in good condition.

4. Contact service center.

1. Disconnect shorted load.
2. See ‘Connecting Electrical

Loads’ section of manual.

3. Contact service center.
4. Contact service center.

1. Turn On/Off Switch to ‘ON’.
2. Charge or replace it.
3. Clean air filter
4. Read and follow directions.
5. Drain and refill tank.
6. Move speed control to “RUN”

position.

  7.  Add oil to proper level.
  8. Contact service center.

  1. Fill fuel tank.

2. Fill crankcase with oil.
3. Contact service center

1. See ‘Connecting Electrical

Loads’ section of manual.

2. Replace the air filter.
3. Contact service center.

Fax

864-834-5127

Toll Free 1-800-845-4141

www.titanindustrial.net

Содержание TG 3800

Страница 1: ...red industrial strength generating unit of electrical power The gas engine and the generator are both potentially extremely hazardous and could cause physical injury or even death if improperly used W...

Страница 2: ...ifications will eliminate the danger of possible carbon monoxide poisoning fire or explosion TWO 2 FEET OF CLEARANCE on all sides is required even while using outdoors This unit is sold solely for the...

Страница 3: ...8126 Replacement Parts 1 800 845 4141 MODEL TG 3800 GAS POWERED GENERATOR The Model TG 3800 operates at 120 volt single phase 60 Hz and will operate devices that require up to 2500 watts Add up the Wa...

Страница 4: ...cal cords or wiring with the genera tor A defective cord may result in electrical shock or may cause damage to equipment Do not expose unit to excessive moisture dirt or corrosive vapors Unit must be...

Страница 5: ...overload the generator Add up the rated Watts of all loads to be connected This total should not exceed the total watts of the genera tor Stopping the engine Turn off all electrical devices connected...

Страница 6: ...il Fired Space Heater 30 000 BTU 150 Airless Paint Sprayer 1 3 HP 600 Handheld Airless Paint Sprayer 150 Radio 50 to 200 Refrigerator 600 Slow Cooker 200 Submersible Pump 1 1 2 HP 2800 Submersible Pum...

Страница 7: ...4 4 1 1 2 2 3 3 5 5 6 6 1 1 2 2...

Страница 8: ...evel 8 Engine has lost compression 1 Out of fuel 2 Low oil level 3 Fault in engine 1 Load is too high 2 Dirty air filter 3 Engine needs to be serviced TROUBLESHOOTING Problem Cause Solution 1 Reset th...

Отзывы: