background image

OPERATION OF THE GENERATOR

Always check the oil level and air filter before
starting the engine.  This unit is equipped with a
low oil system.

NOTE:
Do not allow the handle grip to snap back against
the engine.  Always return it gently to prevent
damage to the starter.

NOTE:
Allow generator to settle.  Run before connecting
any electrical loads or appliances.  Failure to do
so may result in generator damage!

   Connecting electrical loads

Let engine stabilize and warm up for at least 3
minutes.

Make sure devices to be connected are in good
working order and in the “OFF” position before
connecting to the generator.

Make sure to plug in desired devices into the
correct  receptacle.

DO NOT connect 240 Volt loads to the 120 Volt
duplex receptacles.

DO NOT connect 3 phase loads to the genera-
tor.

DO NOT connect 50 Hz loads to the generator.
This is a 60Hz system.

DO NOT overload the generator.  Add up the rated
Watts of all loads to be connected. This total
should not exceed the total watts of the genera-
tor.

   Stopping the engine

Turn off all electrical devices connected to the
generator.

WARNING:
DO NOT start or stop generator with electri-
cal devices plugged in.

Allow the generator engine to run at a ‘No Load’
condition for several minutes to stabilize inter-
nal engine temperature before stopping

   Generator maintenance

      (see maintenance table for list).

Keep the generator clean and dry. Use a damp
cloth to clean exterior surfaces. Remove caked
on dirt with a soft brush.

Never spray with water.  Water can contaminate
the engine fuel system and cause serious prob-
lems in the generator.

Damage  may occur if engine or carburetor clean-
ing products are used.

   Storage

IMPORTANT:

Empty fuel system if unit is to be stored for 30
days or more. This will help prevent gum depos-
its from forming in fuel system such as the car-
buretor,  fuel filter, fuel hose, and fuel tank during
storage.

z

z

z

z

z

z

z

z

z

z

z

z

z

z

z

z

   Starting the engine

z

Содержание TG 3800

Страница 1: ...red industrial strength generating unit of electrical power The gas engine and the generator are both potentially extremely hazardous and could cause physical injury or even death if improperly used W...

Страница 2: ...ifications will eliminate the danger of possible carbon monoxide poisoning fire or explosion TWO 2 FEET OF CLEARANCE on all sides is required even while using outdoors This unit is sold solely for the...

Страница 3: ...8126 Replacement Parts 1 800 845 4141 MODEL TG 3800 GAS POWERED GENERATOR The Model TG 3800 operates at 120 volt single phase 60 Hz and will operate devices that require up to 2500 watts Add up the Wa...

Страница 4: ...cal cords or wiring with the genera tor A defective cord may result in electrical shock or may cause damage to equipment Do not expose unit to excessive moisture dirt or corrosive vapors Unit must be...

Страница 5: ...overload the generator Add up the rated Watts of all loads to be connected This total should not exceed the total watts of the genera tor Stopping the engine Turn off all electrical devices connected...

Страница 6: ...il Fired Space Heater 30 000 BTU 150 Airless Paint Sprayer 1 3 HP 600 Handheld Airless Paint Sprayer 150 Radio 50 to 200 Refrigerator 600 Slow Cooker 200 Submersible Pump 1 1 2 HP 2800 Submersible Pum...

Страница 7: ...4 4 1 1 2 2 3 3 5 5 6 6 1 1 2 2...

Страница 8: ...evel 8 Engine has lost compression 1 Out of fuel 2 Low oil level 3 Fault in engine 1 Load is too high 2 Dirty air filter 3 Engine needs to be serviced TROUBLESHOOTING Problem Cause Solution 1 Reset th...