![Titan Metraflow 240-020 Скачать руководство пользователя страница 10](http://html1.mh-extra.com/html/titan/metraflow-240-020/metraflow-240-020_instruction-manual_1119314010.webp)
10
©Titan Enterprises Ltd 2018
MetraflowManual_v1219
User Settings Tab:
Calibration Settings
This section specifies the units you wish the meter to operate in.
Units:
A drop down menu offers the choice of - Litres, cc, gms, kg,
US gallon, Imperial gallon or Custom units i.e. blank.
Rate (units per):
This is the time base for the flow rate and has the
option of Second, Minute or Hour.
Scale Factor Adjustment
: This is a fine tune adjustment on the
signal to compensate for errors introduced by erratic flow or other
system irregularities
Density:
The flowmeter is fundamentally a volumetric device but a
density figure can be entered here if one of the mass units are
selected. Caution must be used however as there is no
temperature/density correction.
Cut Off:
Flow values below this level will be set to zero.