![Titan Electronics 1XX-M Series Скачать руководство пользователя страница 21](http://html1.mh-extra.com/html/titan-electronics/1xx-m-series/1xx-m-series_user-manual_1119789021.webp)
20
5. SETTING THE PROPER OPERATION MODE
The NCOM-113-M provides various operation modes, including Driver Mode,
RFC2217 Server Mode, RFC2217 Client Mode, Pair Connection Master Mode, Pair
Connection Slave Mode, TCP Raw Server Mode, TCP Raw Client Mode and UDP
Mode. You need to choose the proper operation mode to control your serial devices
located virtually anywhere through a network connection.
Under the “HOME” page of NCOM-113-M’s firmware, select “NETWORK SETTINGS”
to find the “Port 1 Mode Settings” window. Under “Mode”, select the proper
operation mode, check the “Make these the default settings” box and click “Apply
Changes” to set your NCOM-113-M in the proper operation mode.