Table 2: Remote Control Remote Control Codes

Code # Code Type

Description

Code 1

Over Temperature

Temperature is greater than or equal to 95° F while 
the Lights Output is enabled.

Code 2

High Temperature

Temperature is greater than or equal to 95° F for 
an excess of 30 minutes while the Lights output is 
disabled.

Code 3

Low Temperature

Temperature is less than or equal to 45° F for an 
excess of 30 minutes.

Code 4

High Humidity

Humidity above 80% for an excess of 30 minutes.

Code 5

Low Humidity

Humidity below 30% for an excess of 30 minutes.

Code 6

High CO

2

CO

2

 is greater than or equal to 5000 ppm.

Code 7

Empty CO

2

 Tank

Injecting CO

2

 for an excess of 30 minutes and CO

2

 

levels have not reached setpoint (daytime mode 
only).

Code 8

No Measured Light

Light output has been enabled for a minimum of 15 
minutes and no light is detected.

Code 9

No Measured Darkness

Light output has been disabled for a minimum of 15 
minutes and light is detected.

Code 10

Power Interrupted

Unable to complete lighting schedule (power outage 
likely).

Code 20

Temperature Sensor Error Sensor module is unable to get temperature reading 

from temperature detector.

Code 21

RH Sensor Error

Sensor module is unable to get RH reading from 
detector.

Code 22

RH Sensor Saturated

Sensor module has detected that RH detector is 
saturated.

Code 23

CO

2

 Sensor Error

Sensor module is unable to get CO

2

 readings from 

CO

2

 detector.

Code 24

RTC Error

Remote Control is unable to get time from the real 
time clock.

Remote Sensor LED:

The tri-colored LED on the remote sensor is used to display the status 
of the Hyperion

®

 2 by: color, flashes, and blinking frequency. In general, 

green

 LED indicates the controller is functioning normally. When the 

LED is 

yellow

, it indicates that there is a problem with the wireless 

communication. A 

red

 LED is used to indicate an error with the controller 

or one of its sensors. Refer to Table 3 for further details.

Содержание HyperioN 2

Страница 1: ...HyperioN 2 Wireless Environmental Lighting Master Controller Instruction Manual www titancontrols net Product 702880...

Страница 2: ...ontrolling RH with Alternate Exhaust Feature Enabled 9 Checking and Adjusting the Hyperion 2 Settings 10 Checking the Hyperion 2 Control Parameters 10 Figure 3 Hyperion 2 Remote Control 10 Light Timin...

Страница 3: ...odes 19 Calibration 20 CO2 Calibration 20 Figure 4 Bottom View of Remote Sensor 20 Hyperion 2 Wireless Control Network 21 Normal Operation 21 Wireless Control Network Error 21 Table 4 Remote Controlle...

Страница 4: ...nsor and remote controller communicate wirelessly and allow remote monitoring and control of a room s environment All control parameters are changed over the wireless network via the user interface Th...

Страница 5: ...5 120V AC Circuit Remote Controller Exhaust Power 40 Amps 240V AC 60Hz Light Exhaust Output...

Страница 6: ...or Moldule LED section of this document for more information 6 Bring the remote controller in close proximity to the remote sensor so that both the display and the remote sensor s LED shown in Figure...

Страница 7: ...and remote sensor refer to the Wireless Control Network Issues description in the Hyperion 2 Control Network section of this document for further information Daytime Control The Hyperion 2 uses the Da...

Страница 8: ...e Nighttime setpoint This allows the user to tightly control the RH to provide an ideal growing environment Controlling Temperature The Hyperion 2 maintains its environment s temperature as described...

Страница 9: ...etely Details on how to enable disable this feature are given in Alternate Exhaust Mode in the Checking and Adjusting the Hyperion 2 Settings section of this document Controlling RH with Alternate Exh...

Страница 10: ...me during this procedure the display will stop blinking and the system will return to normal operation 1 Follow steps in the Checking The Hyperion 2 Control Parameters and select LIGHTS Press the Sele...

Страница 11: ...own buttons to adjust the minutes of the scheduled time for lights to be activated Press the Select button and the screen will go blank The lighting schedule is now saved and the display will resume n...

Страница 12: ...for instruction on how to replace the battery and reset the remote controller s time Setting the Current Time To avoid making any changes allow 5 seconds with no buttons pressed at any time during th...

Страница 13: ...correct time by following Setting the Current Time instructions listed above Once the time has been set the Low Battery icon will be cleared Note that the lighting schedule will not run until the tim...

Страница 14: ...n To enable disable this feature follow the steps below 1 Enter the adjustment menu on the remote controller by pressing and holding the Menu button until the LIGHTS setting begins to flash 2 Cycle th...

Страница 15: ...s dropped to 86 F or less Exhaust output will remain on until the temperature setpoint has been reached the Lights output will turn on and the controller will resume normal operation The actual on tim...

Страница 16: ...ared when the CO2 levels rise to the desired setpoint No Measured Light Condition When the Hyperion 2 is set to have the Lights output active the remote sensor should detect light and begin using the...

Страница 17: ...ler will show CODE 21 If the problem is resolved the controller will return to normal functionality If the RH detector of the Hyperion 2 s remote sensor becomes saturated with water accurate readings...

Страница 18: ...Darkness Light output has been disabled for a minimum of 15 minutes and light is detected Code 10 Power Interrupted Unable to complete lighting schedule power outage likely Code 20 Temperature Sensor...

Страница 19: ...k section of this document for more information Yellow Normally on flashes off twice Daytime mode unable to communicate with Hyperion 2 Remote Control Yellow Normally off with two yellow flashes Night...

Страница 20: ...nto a 120V AC power source 3 Insert a small non metallic item such as a toothpick through the CO2 calibration buttonhole shown in Figure 4 and press the calibration button for approximately three seco...

Страница 21: ...codes on the remote controller and a yellow LED on the remote sensor indicate problems with the wireless control network All network codes are described below in Table 4 The behavior of the remote sen...

Страница 22: ...document Range Testing Under ideal conditions i e line of sight no metallic interference low humidity etc the Hyperion 2 is capable of communication up to 150 feet Environmental changes and obstacles...

Страница 23: ...the Up and Menu buttons on the remote controller simultaneously until the display begins to blink NETWORK 1 4 Press the Select button and the remote controller will begin searching for the remote sen...

Страница 24: ...mal use for three 3 years from the date of purchase During the warranty period Titan Controls will at our option and without charge repair or replace this product if the controller or any of its compo...

Страница 25: ...the general public FOR WARRANTY SERVICE Please read warranty information first If after reviewing the troubleshooting tips the unit will still not work you should return it to the Dealer where you pu...

Страница 26: ...o shorts or arcing occurring Should you find your circuit breaker keeps tripping check your breakers and equipment to verify that they are the right amperage for your application If you turn OFF the p...

Страница 27: ...Authorization Number Required _____________________________________________ Company Name ____________________________________________________________________________________ Contact Name _____________...

Страница 28: ...1 Square ____ Foot Feet VANCOUVER WASHINGTON U S A Revised 06 29 2017AW 111810 Titan Controls...

Отзывы: