Factory Settings 

 

• Humidity Day Settings: 50% rH  

 

• Humidity Night Settings: 50% rH  

 

• Humidity Dead-Band:  5% rH 

 

Eos

® 

120V High Amperage

 

Digital 

Humidity Controller Overview 

 

The Eos

®

 120V High Amperage Digital Humidity Controller is used to control humidify or 

dehumidify device. You can set your desired day and night relative humidity by adjusting the 

knobs on the front of unit. The adjustment of dial ranges from 5% rH to 90% rH. After setting 

the knobs at the preferred setting, the controller will maintain that setting utilizing a 5% 

differential or dead-band. This Eos

®

 unit provides up to 20 amps of capacity on standard 20 

amp 120 volt circuit. 

Instructions for Operation 

 

Humidity Mode Program 

 

Press both knobs for 3 seconds, turn to select. Press both knobs again to save the setting. 

 

 Humidify Mode: Raises the rH% to a level above the desired set point. 

 

Dehumidify Mode: Lowers the rH% to a level below the desired set point. 

 

Day & Night Humidity Set Point 

Press each knob and turn to set the Day and Night humidity, press again to confirm the 

setting. 

 

Humidity Dead-Band (hysteresis): 5% rH 

 

For example, when using Dehumidify, if the set-point is 45% rH and the dead-band is 5%, 

the Humidity output will activate at or above 45% rH and will deactivate at 40% rH. For 

Humidify mode, if the set-point is 45% rH, the output will activate at or below 45% rH and 

deactivate at 50% rH 

  

Humidity Min/Max Recall 

 

Click both humidity (Day or Night) knobs to display the Humidity min/max rH record. This 

shows the lowest rH and highest rH levels for a 24 hour period. The screen will return to 

normal display after 5 seconds or by a pressing both knobs, and the record will be reset. 

 

Day and Night Mode  

Day Mode: Humidity device works when the photocell senses light. 

 

Night Mode: Humidity device works when the photocell senses darkness. 

 

24 Hours: Humidity device works during both day and night. This option utilizes both the 

programmed DAY and NIGHT humidity settings. In 24 hours mode, the settings are locked 

and cannot be adjusted. The controller must be switched to DAY or NIGHT mode to change 

the humidity setting.

3

Содержание EOS 702603

Страница 1: ...EOS 120V High Amperage Digital Humidity Controller Instruction Manual Part 702603 www titancontrols net...

Страница 2: ...Breaking tamper proof seal will void your warranty Do not put paper clips tools etc into unit Possible electrocution may occur Plug controller into surge protector to avoid potential damage to the un...

Страница 3: ...Point Press each knob and turn to set the Day and Night humidity press again to confirm the setting Humidity Dead Band hysteresis 5 rH For example when using Dehumidify if the set point is 45 rH and t...

Страница 4: ...er s max amperage rating 20 A Controller Specifications Max Amp 20 amps 120V 60Hz Sensor Cord Length 15 ft Humidity Range 5 90 rH Humidity Accuracy 3 rH Humidity Dead Band Hysteresis 5 rH Weight 2 1lb...

Страница 5: ...Installation Options Option 1 Secure the unit to a wall Option 2 Screw the controller to the grow tent tube with a U bolt Installation Example 5 Remote Sensor 120 Volt 120V 20Amps Circuit...

Страница 6: ...Controls Monetary refunds of the warranty will not be given The Buyer assumes all responsibility regarding the use installation of this controller All warranty service is provided through the factory...

Страница 7: ...__________________________________ Shipping address will be given when the RMA is issued WARRANTY SERVICE Please read warranty information first If after reviewing the troubleshooting tips the unit wi...

Страница 8: ...______________________________________________ _________________________________________________ _________________________________________________ _________________________________________________ ___...

Отзывы: