4.3.7 Model Setting 
In alarm system, press “Model setting” icon to enter model setting interface.

In model setting interface, three optional models including "In home model”, 

“Evening model”, “Leaving model" will be shown at the top of the interface. 

Press the model you want to set. "Setting" option represents arm delay time 

and "Reporting" means alarm delay time. Click “on or off” button to turn 

on/off the area. When the setting is done, press        icon at the bottom of the

 interface to complete the setup. 

4.3.6 Alarm Record

In alarm system interface, press “Alarm record” icon to enter “View alarm 

record” interface and then you can view and sort out alarm records. 

4.3.4 Disarm

In alarm system interface, press “off” icon to bring out disarm model 

interface which requires you to input disarm password. Using the numeric 

keypad on the screen to enter the password set disarm (default disarm 

password is "0000", default hijack code is "0001"), and press "Ok" icon at 

the bottom of the interface to disarm the system.

4.3.5 Disarm Password

Press “Off code” in alarm system interface to access disarm password 

inputting interface, and then enter disarm password to enter the password 

setting interface. In the interface, you can set the master password and 

hijack code (hijack code is master pa1). Enter the old password 

(default old password is "0000") into "Old pwd" bar on numeric keypad, 

and then enter the new password you want to set into "New pwd" bar. 

Re-enter the new password into "Sure pwd" bar and press “Ok” icon at the 

bottom of the interface. If the interface prompts that the password has 

been saved, it means the new password is set successfully.

4.3.8 Alarm Area State

In alarm system interface, click “Alarm state” icon to enter alarm area 

status interface. Here you can check the status of all alarm areas.

Содержание TIP-DPH-INT7

Страница 1: ...al Video Doorphone Indoor Unit Basic Function UI Interface Introduction and Operation Instruction Installation Instruction Technical Specification Product Overview Product Description 1 1 2 3 18 19 TI...

Страница 2: ...and multi media entertainment all in one Status Icon Name Night Mode Home Mode Leave Mode Message Missed Calls Network connected Network disconnected Melody status Monitor Call Management Unit Call Me...

Страница 3: ...d Operation Instruction At first boot the interface for inputting D code will appear When there is no management center according to the network topological graph in simple presentation just simply co...

Страница 4: ...therwise please enter two digit building number plus two digit unit number plus four digit room number If the number entered is wrong you can press backspace key to modify For example to call Room 105...

Страница 5: ...l switch to those of next outdoor unit or fence unit The switch will circulate according to quantity of the actual installed outdoor units and fence units 4 2 2 Monitor Indoor Before you monitor throu...

Страница 6: ...the numeric keypad on the screen to enter the password set disarm default disarm password is 0000 default hijack code is 0001 and press Ok icon at the bottom of the interface to disarm the system 4 3...

Страница 7: ...ce select the entry you want to view press Read icon to enter messages playing interface and the message will be played Press Pause button to pause during the playing and then press Play button to con...

Страница 8: ...e System setting consists of display sound time system information project setting etc a Select Music icon in the menu Press icon to play music b Press to play previous song and press to play next son...

Страница 9: ...set and input number by using the numeric keypad on the screen Press Ok icon to finish the setting Press to modify month directly press the calendar to modify current date and finally press save it 4...

Страница 10: ...restore the factory settings etc Input project password the default is 3888 to enter project setting interface 4 11 1 IP Address and Room Number Setting Press Addr setting icon in the project settings...

Страница 11: ...hroom Sensor type includes infrared magnet smoke gas and emergency Trigger way includes normal closed normal open 3 state low level the unit will alarm when it is in low level equipment installation s...

Страница 12: ...n 204 x 134 x 18 5mm 21 22 5 2 Wiring Diagram Installation Instruction 5 1 Topological Graph High level area High level area Multi level area Multi level area Smoke Infrared Alarm Switch Indoor unit S...

Отзывы: