INSTALLATION MANUAL
MODEL: MRS-AC10G
TIS CONTROL LIMITED
RM 1502-p9 Easey CommBldg
253-261 Hennessy Rd Wanchai
Hong Kong
TEXAS INTELLIGENT SYSTEM LLC
SUITE# 610. 860 NORTH DOROTHY DR
RICHARDSON
TX 75081.USA
Copyright © 2020 TIS, All Rights Reserved
TIS Logo is a Registered Trademark of Texas Intelligent System LLC in the
United States of America. This company takes TIS Control Ltd. in other
countries. All of the Specifications are subject to change without notice.
w w w . t i s c o n t r o l . c o m
MARS 10 GANGS WALL PANEL WITH THERMOSTAT
LIGHTING CONNECTION
▸
Connect the live wire to com
▸
Connect the loads wire to Out1-Out3
to terminals
▸
Connect load neutral wire to main
neutral in the distributor box.
CURTAIN CONNECTION
▸
Connect the Supply wire to COM
▸
Connect the Open wire to OUT1
▸
Connect the Close wire to OUT2
▸
Shutter neutral connection, if it exists,
can be looped to main neutral in the
distributor box.
GND(white-orange)&(white-brown)
D-(white-green)&(white-blue)
D+(blue-green)
24+V(brown-orange)
Cat5e connection
1.5 mm Electric Cable
1.5 mm Electric Cable
2.5 mm Electric Cable
PANEL ADDITION
3 Output Relay 5 Amp
Model : ADD3-R5-A
TIS BUS Input : 75-45mA/24V DC
Output Current : 3A220VAC
COM OUT3 OUT2 OUT1 COM
w
ww
.tis
smar
thome.com
D-
24+V
GND
D+
Connect To L
O-OFF
I-ON
MCB
Open
Close
220 ~ 110 Volt
Connect To N
To the TIS BUS Network
Cat5e
Mars 10G
PANEL ADDITION
3 Output Relay 5 Amp
Model : ADD-3R-5A
TIS BUS Input : 45-75mA/24V DC
Output Current : 3A220VAC
COM OUT3 OUT2 OUT1 COM
www
.tissmar
thome.com
D-
+24V
GND
D+
To the TIS BUS Network
Cat5e
GND(white-orange)&(white-brown)
D-(white-green)&(white-blue)
D+(blue-green)
+24V(brown-orange)
Cat5e connection
1.5 mm Electric Cable
1.5 mm Electric Cable
2.5 mm Electric Cable
Connect To L
O-OFF
I-ON
MCB
Connect To N
Mars 10G
INSTALLATION STEPS
FOR PANEL ADDITION 3R-5A
WARNING:
Set the curtain function in the
software before connecting the wires.