MARS 10 GANGS WALL PANEL WITH THERMOSTAT
FOR PANEL ADDITION 2DL-IRR
You can connect 2 digital inputs to any
switch or window magnet.
GND(white-orange)&(white-brown)
D-(white-green)&(white-blue)
D+(blue-green)
+24V(brown-orange)
Cat5e connection
low voltage cable
low voltage cable
low voltage cable
PANEL ADDITION
2 Digital Input with IR Receiver
Model : ADD-2DL-IRR
TIS BUS Input : 45mA/24V DC
VCC REC GND Z2
Z1
www
.tissmar
thom
e.com
D-
+24V
GND
D+
TIS IR Receiver probe
To the TIS BUS Network
Cat5e
Mars 10G
PANEL ADDITION
2 Digital Input with IR Receiver
Model : ADD-2DL-IRR
TIS BUS Input : 45mA/24V DC
VCC REC GND Z2
Z1
www
.tissmarthome.com
D-
+24V
GND
D+
To the TIS BUS Network
Cat5e
GND(white-orange)&(white-brown)
D-(white-green)&(white-blue)
D+(blue-green)
+24V(brown-orange)
Cat5
e
connection
low voltage cable
low voltage cable
Traditional Switch
L
S2
S1
S1
L
L
S2
INSTALLATION STEPS
7
Connect the other connection if needed as per the panel addition type:
You can add an External Infrared Receiver
to the IRR Port, connect as follows:
▸
the IR Receiver black wire to GND
▸
Gray wire to REC
▸
Red wire to VCC Terminal.