background image

is made easier by the exhaled gas higher 

temperature;  moreover,  two  exhaust 

valves,  each  one  having  a  membrane, 

are provided to allow the emptying of the 

canister even during the dive. The canister 

plug  with  bayonet  coupling  is  furnished 

with  an  o-ring  washer  that  warrants  a 

perfect sealing.

If the canister is not used for long periods, 

the plug could become hard to open and 

more effort would be necessary, but this is normal as it is due to a stronger o-ring friction. 

Note:always verify the integrity and the clearness of the o-ring washer on the closing plug as 

it could show signs of filtering material dust. Also always check that the o-ring is correctly 

positioned.

7) USER AND MAINTENANCE GUIDEBOOK 

Each  underwater  breathing  apparatus  is  delivered  with  the  present  producer  information 

guidebook  and  a  warranty  as  well  as  an  user  and  maintenance  guidebook  that  should  be 

carefully read by the user. The warranty must be filled in and sent to the producer for validation; 

the producer declares no responsibility in case the user does not respect instruction given in 

the forementioned guidebooks, or for the incorrect use and maintenance of the product and its 

parts. 

The user and maintenance guidebook and the present information leaflet integrate but in no case 

substitute a proper diving course held by qualified trainers. 

Note: in case your underwater breathing apparatus has been delivered without an user and 

maintenance guidebook, please request it before using our product. 

8) INTEGRATED ALTERNATE SOURCE 

The  use  of  the  underwater  breathing  apparatus  TIR/

SPACE  does  not  exclude  the  presence  of  an  open 

circuit alternate air source, as it can be chosen by the 

user. It can be connected to the main pressure reducer 

or a traditional open circuit regulator connected to the 

second valve can be used.

In  the  first  case,  if  the  tank  has  a  single  connection, 

to  connect  to  the  main  pressure  reducer  the  second 

stage  should  be  a  balance  power-assisted  type  as  the 

“OXIGEN  and  K50”model  available  on  request  (optional);  in  the  second  case,  having  two 

connections  valves  (preferably)  a  traditional  open  circuit  regulator  could  be  connected  to 

the second valve, however it would be better to use a specific balance power-assisted Nitrox 

model.

Note:  before  diving,  always  and  carefully  verify  that  no  loss  of  gas  occurs  through  the 

connections  to  the  valves  and  that  the  second  stage  is  not  free  flowing;  in  both  cases  the 

estimate 

endurance is reduced

.

Содержание space 40

Страница 1: ......

Страница 2: ...on the tank for unexpected events the logic consequence is a reduction of bubbles more then 90 compared to a traditional open circuit In short if at depth of 30 mt 100 ft while using an open circuit a...

Страница 3: ...underwater breathing apparatus on the market having the same aims and final employment destination From 2005 Claudio Beux has had the chance to use and perfectionate all the prototypes obtained by ma...

Страница 4: ...leasant sensation experienced while riding a motorcycle at speed of 50 km 62 miles per hour and breathing open mouthed The most competitive The use of injection moulds for the manufacturing in mass pr...

Страница 5: ...in temperature of the breathed gas that will not make the diver notice water temperature even when it is cold Physicians claim that a diver s oxygen consumption can be an average of 1 5 lt per minute...

Страница 6: ...o that the diver will overcome immediately a possible critical situation likewise the diver will be able to do the cleaning of the counterlung whenever they think it necessary by simply exhaling from...

Страница 7: ...ed of two light alloy tanks with a capacity that can vary from 3 to 8 80 pints 200 bars pressure reducers are in TITANIUM as well the sonic filter endurance 120 minutes can be doubled as necessary for...

Страница 8: ...e 40 stays into the limits required and indicated on the graphic even at the depth of 42 3 meters In chart B it is possible to see that the Space 40 stays into the limits required and indicated on the...

Страница 9: ...14 5 lt for 32 of oxygen 4 A complete Buoyancy Control Device with strengthened technopolimer backholder or as optional in stainless steel 5 A standard analogic underwater gauge or the AIR LIMIT MONOM...

Страница 10: ...o 25x2 are available it reduces tank pressure from 200 300 bars to 13 13 5 bars it is furnished of 3 low pressure outlet 3 8 unf and 2 high pressure outlet 7 16 unf appropriately signed HP Note we sug...

Страница 11: ...a normal rear lift capacity type Buoyancy Control Device For those who travel an equipment is provided a belt with quick release buckles and two adjustments that allow to wear underwater breathing app...

Страница 12: ...it is absolutely necessary to replace the Sofnolime filter before colour changes use of a filter no more able to withhold carbon dioxide is extremely dangerous The filtering cartridge made of transpa...

Страница 13: ...use and maintenance of the product and its parts The user and maintenance guidebook and the present information leaflet integrate but in no case substitute a proper diving course held by qualified tr...

Страница 14: ...p and finally regulate tension correctly Remember that during the dive straps will losen because of wet suite crushing check that the mouthpiece lever is closed connect the blue coloured hoses coming...

Страница 15: ...ul periodical maintenance in addition to after dive washing similarly to a traditional underwater open circuit breathing apparatus also the underwater breathing apparatus with partial recycling of exh...

Страница 16: ...ning of the ring nut that presses down on the membrane as the counterlung can be closed only in one direction inflate the counterlung and close the mouthpiece lever then with a light pressure on the m...

Страница 17: ......

Отзывы: