Содержание space 40

Страница 1: ......

Страница 2: ...on the tank for unexpected events the logic consequence is a reduction of bubbles more then 90 compared to a traditional open circuit In short if at depth of 30 mt 100 ft while using an open circuit a...

Страница 3: ...underwater breathing apparatus on the market having the same aims and final employment destination From 2005 Claudio Beux has had the chance to use and perfectionate all the prototypes obtained by ma...

Страница 4: ...leasant sensation experienced while riding a motorcycle at speed of 50 km 62 miles per hour and breathing open mouthed The most competitive The use of injection moulds for the manufacturing in mass pr...

Страница 5: ...in temperature of the breathed gas that will not make the diver notice water temperature even when it is cold Physicians claim that a diver s oxygen consumption can be an average of 1 5 lt per minute...

Страница 6: ...o that the diver will overcome immediately a possible critical situation likewise the diver will be able to do the cleaning of the counterlung whenever they think it necessary by simply exhaling from...

Страница 7: ...ed of two light alloy tanks with a capacity that can vary from 3 to 8 80 pints 200 bars pressure reducers are in TITANIUM as well the sonic filter endurance 120 minutes can be doubled as necessary for...

Страница 8: ...e 40 stays into the limits required and indicated on the graphic even at the depth of 42 3 meters In chart B it is possible to see that the Space 40 stays into the limits required and indicated on the...

Страница 9: ...14 5 lt for 32 of oxygen 4 A complete Buoyancy Control Device with strengthened technopolimer backholder or as optional in stainless steel 5 A standard analogic underwater gauge or the AIR LIMIT MONOM...

Страница 10: ...o 25x2 are available it reduces tank pressure from 200 300 bars to 13 13 5 bars it is furnished of 3 low pressure outlet 3 8 unf and 2 high pressure outlet 7 16 unf appropriately signed HP Note we sug...

Страница 11: ...a normal rear lift capacity type Buoyancy Control Device For those who travel an equipment is provided a belt with quick release buckles and two adjustments that allow to wear underwater breathing app...

Страница 12: ...it is absolutely necessary to replace the Sofnolime filter before colour changes use of a filter no more able to withhold carbon dioxide is extremely dangerous The filtering cartridge made of transpa...

Страница 13: ...use and maintenance of the product and its parts The user and maintenance guidebook and the present information leaflet integrate but in no case substitute a proper diving course held by qualified tr...

Страница 14: ...p and finally regulate tension correctly Remember that during the dive straps will losen because of wet suite crushing check that the mouthpiece lever is closed connect the blue coloured hoses coming...

Страница 15: ...ul periodical maintenance in addition to after dive washing similarly to a traditional underwater open circuit breathing apparatus also the underwater breathing apparatus with partial recycling of exh...

Страница 16: ...ning of the ring nut that presses down on the membrane as the counterlung can be closed only in one direction inflate the counterlung and close the mouthpiece lever then with a light pressure on the m...