2
used in virtually all weathers, regardless of whether the sun is shining strongly or it is cloudy. If the energy that is
absorbed is insufficient to operate the pump, it is operated via battery
This device has been developed for private use and not for industrial or commercial purposes.
This device has been developed for private use and not for industrial or commercial purposes.
The pump is not suitable for displacement of salt water, faecal matter, flammable, corrosive or other hazardous liquids.
The pumped liquid must not exceed the maximum temperature specified in the technical data.
4.
Technical data
Model
SBS 36
Pump operating voltage
3.7 V DC
Pump rated power
2 Watt
Degree of protection for pump
IPX4
Degree of protection for control housing / collector
IPX4 / IPX4
Collector rated power
0.7 Watt
Max. flow rate (Q
max
)
1)
36 l/h
Max. delivery head (H
max
)
1)
3 m
Max. suction height
2 m
Hose lenght
7 m
Maximum temperature of the pumped liquid (T
max
)
35 °C
Battery type
3.7 V / 2,000 mAh / Li-Ion
Weight (net)
ca. 1.1 kg
Item number
30446
1)
The specified maximum capacities have been determined with a free, unreduced outlet.
5.
Scope of delivery
6. Assembly / disassembly
Important! The pump must not run dry. Otherwise, the possibility of damage to the device cannot be ruled
out!
The numbers specified in the following text refer to figures I and II at the end of the operating manual.
•
Unpack all components carefully.
•
Affix the control unit (1) using the above-lying mounting holes. Make sure that the control unit is attached at a
suitable location, above the water surface and protected from strong weather conditions.
•
Affix the ground spike to the solar collector's frame side (2). We recommend securing the ground spike to the long
sides of the collector for stability reasons.
•
Press the ground spike with the collector installed on it into a soft substrate such as grass.
•
Point the collector surface to the south and ensure that the surface is not in the shadows.
•
Connect the solar collector (2) to the right connection (
) of the control unit.
•
Now connect the filter (3) to the control unit at the left connection ( ).
1
Control unit with pump
2
Solar panel with connection cable
and ground spike
3
Filter with float switch
4
7 m hose (Ø 5 mm)
5
T-piece (16 pcs.)
6
Hose holder (15 pcs.)
7
Drip outlets (15 pcs.)
8
Check valve
9
Sealing plugs
Operating instructions
8
Содержание SBS 36
Страница 51: ......