background image

Catalog No.:  6000.342D 

Effective:  9-01-09 

Replaces:  6-22-08

 

Job:  

         

 

Engineer:  

         

 

 

Contractor:  

         

 

 

Prepared By:  

         

 

  Date:   

         

 

 

Model:   

         

 

  Indoor/Outdoor:   

         

 

   MBTUH Input:   

         

 

 

 
Sealed Combustion Chamber 
100% Factory Fire Tested 
Efficiency: 85% 
Minimum Non-condensing Inlet Temperature: 105°F 
Thermal Shock Proof Heat Exchanger 
Limited Twenty-year Thermal Shock Warranty 
Limited Five-year Heat Exchanger Warranty 
Full Safety Diagnostics with Fault History 
PolyTuf Powder Coated Cabinet 
No Combustible Floor Shield Required 
Fan-assisted 
Non-ferrous Bypass 
Patented Burner Security Blanket 

 

 
Heat Exchanger 

ƒ

 Brass 

Headers 

ƒ

  ASME Inspected and Stamped 

160 PSIG Working Pressure 

ƒ

  National Board Approved 

ƒ

  Cupro Nickel Finned Tubing 

ƒ

  ASME Steel Tube Sheet 

ƒ

  Silicone High Temp O-Rings 

ƒ

  125 PSIG ASME Pressure Relief Valve 

ƒ

  Temperature and Pressure Gauge 

ƒ

 Water 

Connections 

 Left – Standard  
 Right – Option A-6 

ƒ

  Bronze Pump, 120V, 60Hz 

ƒ

  Non-ferrous Pool Bypass 

 

Controls 

ƒ

  120V, 60Hz, 1

 Power Supply 

ƒ

  120/24V 60Hz Transformer 

ƒ

 100% 

Shut-off/Lockout 

ƒ

  Hot Surface Ignition Systems (2) 

ƒ

  Remote Flame Sensors (2) 

ƒ

  High Limit Control, Auto Reset 

ƒ

  On/Off Power Switch 

ƒ

  Manual Shut-off, Front-mounted 

ƒ

 Flow 

Switch 

ƒ

  Blocked Vent Pressure Switch 

ƒ

  Combustion Air Proving Switches 

ƒ

  Economaster Pump Time Delay 

ƒ

 Poolstat 

ƒ

  Diagnostic Panel with LCD Display 

2 Lines, 20 Characters 

 
Gas Train 

ƒ

 Combination 

Valves 

ƒ

 On/Off 

Firing 

ƒ

  Low Gas Pressure Switch, Manual 

ƒ

 Fuel 

 Natural Gas 
 Propane Gas 

ƒ

  Design Certified ANSI Z21.56/ 

CSA 4.7 (P models) 

ƒ

  Design Certified ANSI Z21.10.3/ 

CSA 4.3 (WHP models) 

 

Burner 

ƒ

 Ultra-low 

NOx: 

Less than 20 PPM 

 

Construction 

ƒ

 Indoor/Outdoor 

Construction 

ƒ

  Enclosed Front Controls 

 

Venting 

ƒ

 Vent 

Location 

 

 Top – Standard 
 Rear – Option D-14 

ƒ

  Vent Termination Cap 

 Outdoor – Option D-11 
 Indoor, Horizontal –  

Option D-15 

 Indoor, Vertical (by others) 

ƒ

 Combustion 

Air 

 In-Line Filter Kit (TruSeal  

only) – Option D-17 

 Air Intake Elbow –  

Option D-16 

 
Options 

 C-6 

Ignition Module, Manual Reset 

 D-21  TruSeal™ Direct Vent 

 

 Right Side 

 

 Left Side (Model 1802B   

 Only) 

 F-10  Low Water Cut-off, Remote 

Probe 

 P-__  Cold Water Run System 

 

(See Page 3) 

 S-2 

Dual High Gas Pressure 
Switches, Manual Reset 

 X-1 

SureRack Kit 

 X-2 

SureRack Kit  Above Grade 
Add-on (used with X-1) 

 Y-241  Temperature Controller,  

1-4 Stages 

 

Regulatory Agency Requirements 

 G-1 

CSD-1 

 

 
 
 
 
 
 
 

  

  

 

Hi Delta

®

 

- Type P

   Commercial Pool Heaters 

Models 1802B-2342B

Standard “H” Bypass Shown

Patent No. 7,044,124 