Troubleshooting

Code

Description

Solution

СС01

Intake air temperature is higher than 
permitted

Wait until the ambient conditions match 
the operating conditions of the device

СС02

Intake air temperature is lower than 
permitted

СС03

The temperature of the control board 
exceeds the permitted value

Disconnect the device from the power 

supply for 10–15 seconds (unplug the 
power cord from the outlet) and then 

reconnect it
If this does not resolve the issue, please 
make note of the error code and contact 
Tion Smart Microclimate Customer 
Service or your nearest authorized 
service center

СС04

The temperature of the control board is 
lower than the permitted value

EC01, EC02, 
EC03

Damper operation error

Write down the error code
Disconnect the device from the power 

supply for 10–15 seconds (unplug the 
power cord from the outlet) and then 

reconnect it

EC04, EC05, 
EC06, EC11

Heater operation error

EC07, EC08, 
EC09, EC10

Temperature measurement error

If you cannot resolve the issue yourself, please contact the Tion Smart 
microclimate, JSC service department or the nearest authorized service center.

Device serial number locations

Warranty card

Device

Содержание Breezer Lite

Страница 1: ...ply ventilation device We care about the environment and strive not to create unnecessary printed materials For that reason please choose a language and scan the code Breezer Lite tion global tion ru...

Страница 2: ...Breezer Lite Dear user Thank you for buying this compact supply ventilation device BreatheCleanAir...

Страница 3: ...eneral information 4 Device and package contents 5 Getting started 6 Display 7 Controls 9 Filter maintenance and replacement 11 Troubleshooting 12 Specification 13 Safety 14 Other requirements 16 Warr...

Страница 4: ...ify it Takes air from outside Purifies1 Heats2 Provides clean air to the room Windows are closed Fresh air enters the room Contaminated air is forced out into the exhaust openings 1 Cleaning is carrie...

Страница 5: ...The purification class of the supplied filter is indicated on the device box Filters of different classes are interchangeable Deviceandpackagecontents 1 device 2 heater adapter3 3 duct filter4 G4 duc...

Страница 6: ...e phase with protective grounding Protective grounding is a mandatory requirement for operating the device Turn on The yellow light on the front panel will light up when the device is connected to the...

Страница 7: ...r opening the device menu in the Tion Remote mobile app Standby mode Operation mode at speeds 1 and 2 Operation mode at speeds 3 and 4 Operation mode at speeds 5 and 6 The heating temperature is set t...

Страница 8: ...Setting target temperature 2 Switch to Pairing mode 2 The device has been successfully paired with a smartphone 3 There is a pairing error between the device and smartphone 3 Switching to Warning mode...

Страница 9: ...itions match the operating conditions Error the device damper is closed the fan does not operate there are three red indicator lights Please refer to the Troubleshooting section of this document when...

Страница 10: ...low light Press and hold the button until a flashing blue light appears 2 Press the Power button on the remote control The remote and the breezer will now pair 3 The remote control display will show t...

Страница 11: ...11 Filter maintance and replacement 1 5 2 6 3 7 4 8 3s After replacing the filter reset the filter life meter using the remote control or the Tion Remote mobile app...

Страница 12: ...of the error code and contact Tion Smart Microclimate Customer Service or your nearest authorized service center 04 The temperature of the control board is lower than the permitted value EC01 EC02 EC...

Страница 13: ...Hz 230 50 230 50 Net mass kg 3 2 8 Dimensions mm 260 260 130 260 260 130 Operational lifetime years 5 5 8 The specifications listed are only guaranteed provided that the device is used with the Tion...

Страница 14: ...alterations made to the design of the device Do not activate the device if the power supply cord insulation or any part of the housing is damaged If the power supply cord is damaged it must be replac...

Страница 15: ...gain for error codes 10 minutes after the beep then unplug the device from the socket Otherwise the shutter will remain open and outside air will be able to flow through the device into the premises D...

Страница 16: ...ided installation is conducted correctly and that the rules of operation are followed Upon the expiration of the product s service life please discontinue using the device and contact the Vendor s ser...

Страница 17: ...ce manufacture purchase date cannot be determined due to the absence removal or damage to the ID information the device was damaged by events or third party actions outside the Vendor s Manufacturer s...

Страница 18: ...at tion ru about doc This device is compliant with 2014 35 EU Low Voltage Directive 2014 30 EU Electromagnetic Compatibility Equipment Directive 2014 53 EU Radio Equipment Directive 2015 863 EU Restr...

Страница 19: ...partment service tion ru tion ru service Manufacturer Tion Smart microclimate JSC Office 112 20 Inzhenernaya St Novosibirsk Russia 630090 Factory Hanking Plastic Manufactory ShenZhen Co Limited 16 Xih...

Страница 20: ...Lite _ _...

Страница 21: ...21 22 23 24 25 27 29 30 31 32 34 36 38 39 tion ru...

Страница 22: ...22 Tion Lite 1 2 1 2 Tion Lite Eco...

Страница 23: ...23 1 3 6 2 4 7 5 3 Tion Lite Eco 4 1 2 3 3 4 G4 EPA E11 4 5 6 7...

Страница 24: ...24 3 230 50 3 1 2 QR...

Страница 25: ...25 20 20 Tion Remote 1 2 3 4 5 6 0 10 20 25 30...

Страница 26: ...26 1 2 1 2 5 1 2 2 3 3 3 4 6 5...

Страница 27: ...27 1 2 3 3 3 1 2 4 6 1 10 20 25 0 3 3 3...

Страница 28: ...28 Tion Remote Tion Remote 1 6 Tion Remote Bluetooth 2 5 1 7 2 Power 3 6 iOS 11 0 Android 5 0 7 3 5c 5 10 QR tion ru...

Страница 29: ...29 1 5 2 6 3 7 4 8 3 Tion Remote...

Страница 30: ...30 01 02 03 10 15 04 EC01 EC02 EC03 10 15 EC04 EC05 EC06 EC11 EC07 EC08 EC09 EC10...

Страница 31: ...31 8 Lite Lite ECO 9 900 50 850 C 25 50 0 50 50 50 10 3 100 100 230 50 230 50 3 2 8 260 260 130 260 260 130 5 5 8 9 IEC 60335 1 2015 10 1 10...

Страница 32: ...32 2...

Страница 33: ...33 10 35 80 35 10...

Страница 34: ...34 1 40 40 2 80 25 3 4 1 5 5...

Страница 35: ...35...

Страница 36: ...36 2...

Страница 37: ...37...

Страница 38: ...38 tion ru about doc 004 2011 020 2011 037 2016...

Страница 39: ...8 800 500 78 32 servi e tion ru tion ru service 630090 20 112 7 800 500 60 29 Hanking Plastic Manufactory ShenZhen Co Limited No 16 Xihutang street Longgang District Shenzhen city 518117 P R China 2 0...

Страница 40: ...40...

Страница 41: ...41...

Страница 42: ...42...

Страница 43: ......

Страница 44: ...BreatheCleanAir _ _...

Отзывы: