Tel: (909) 890-0700
Fax: (909) 890-0736
P.
O.
B
OX
1667
S
AN
B
ERNARDINO
,
C
A
92402
Web: www.tinker-rasor.com
E-mail: [email protected]
- 5 -
Sponsoring members of NACE International, NACE Foundation
QMF-570
112-071
P
RODUCT
I
NSTRUCTIONS
D. Place the stationary Black probe needle point against the metal at one end of the conductive material.
E.
Place the Red probe approximately 1” (25 mm) away from the Black probe. The LCD shows one or two
bars only, very close to the “0” at the far Left of the display.
F. Move the Red probe as far away from the Black probe as the wire will allow. Note the LCD shows bars
almost all the way to the Right, near the
“100”. There should be one bar not shown on the display.
G. Mark the position of the Black probe and the far position of the Red probe.
H. Find the center point between the marks. Place the Black probe at the Black probe mark and move the
Red probe to the center mark. The LCD should show bars to the center point of the display.
I.
In the same manner as above, make marks at the 25% and 75% distances between the Black and Red
probe marks. At these distances, the LCD should show bars at about 25% to the Right and 75% to the
Right, respectively.
J. If the meter agrees with the where the needle points are located on this scale, to an approximation of +/-
2 bars, then the RF/IT is considered to be tuned correctly. If there is a discrepancy, the RF/IT should be
returned to Tinker & Rasor for factory tuning.
USE OF SOLID STATE DECOUPLERS
An insulating joint protected by a solid state decoupler may show as a short to the Model RF/IT. To
ensure a proper test with the RF/IT, the decoupler should be removed and retested. Please refer to the
decoupling device manufacturers recommendations and instructions for removal.
SERVICE & SHIPPING INSTRUCTIONS
All instruments being returned for repair should be sent PREPAID to either address below:
Tinker & Rasor
ATTN: Repair
791 S. Waterman Ave
San Bernardino, CA 92408
Or by USPS:
P.O. Box 1667
San Bernardino, CA 92402
Include with shipment information the nature of the problem, purchase order, serial number and return delivery
address. Immediate service is guaranteed!
There is an online form to fill out, print and return with your repair / calibration. You can find the form on the Tinker
& Rasor website, under Contact Us menu: www.tinker-rasor.com
102-138