Battery  condition  indicated  on  the  LCD  meter  when  replacement  needed.  For  best  results,  use  with  a  fresh  9v 
battery.    (Older  RF/IT  use  (6) 

“AA”  size  alkaline  batteries)  The  Tester  will  operate  properly  until  output  battery 

voltage drops to 7 volts DC. 
 

Note: The display will flash when the batteries are low. 

 

 
Pre-operation check of the Model RF/IT Tester

 

 
A.  Remove Black probe from lid of case 

and “INSERT” into either port locator on the front end of Tester. 

B.  Remove red probe from lid of case 

and “INSERT” into the other port on the front end of Tester. 

C.  Unscrew the knurled end of each probe to loosen the tip. Remove the tip and invert it back into the probe. 

Each probe uses a very sharp, needle point tip, which are shipped and stored backwards for safety. The 
sharp  point  of  each  tip  is  necessary  to  get  under  any  coatings  on  the  surface  to  be  tested.  Tighten  the 
knurled end back down. 

D. 

Turn Tester “ON”  

E.  Observe LCD meter.  The indicators should be all the way to the Right or the 

“100” end of the scale. (On 

older models, the meter should show solid black square dots completely across the top and the bottom of 
the meter face. Between the bars, at each side, two black arrows should flash slowly.) 

The tester is equipped with audible signal and tone frequency varies from slow to fast according to 
resistance across probes. The lower the electrical resistance of the insulator the faster the frequency of 
the audible signal. A short will sound as a continuous beep. Test this by shorting the two probe tips to one 
another, and hear the continuous beep, and the meter deflect all the way to the Left. 

F.  Tester is now ready to operate. 

 

OPERATION TO CHECK SINGLE IN-LINE INSULATOR 

 

A. 

Place solid “black” probe’s steel  point on one side of insulator, making positive  electrical contact to  the 
metal pipe. 

B. 

Place the flexible cable “red” probe’s steel needle to  the opposite side of the insulator, making positive 
electrical contact to the metal pipe. 

C. 

If insulator is “shorted”, (low electrical resistance” the LCD meter will show  down low (Left) towards the 
“0”. (On older meters, only one or two black square dot on both top and bottom rows on the LCD meter). 

D.  If the LCD meter reads 

all the way to the “100”, the insulator is performing extremely well. (Older meter 

shows black square dots completely across the top and bottom rows) 

E.  LCD meter readings between these two extremes gives the operator the degree of quality of the insulator. 

The  lower  the  LCD  meter  readings,  the  lower  the  electrical  resistance  of  the  insulator.  Low  resistance 
reading may be cause to watch for impending failure. 

F.  It is recommended that the RF/IT probes be used to take multiple measurements at locations around the 

circumference  of  the  flange. 

On  large  diameter  flanges,  greater  than  16”  diameter,  readings  should  be 

made at each clock position around the circumference. (12 

o’clock, 1 o’clock, 2 o’clock, etc) 

 