background image

 

TBB4  User  Manual 

 

 

Version E May 2020 

 

7.2

 

Cycle test curve 

Sample  12V battery cell 

Steps 

1-49

th

 times 

2.0Ah 

1.2Ah 

Cycle 

300 times (memo each 50

th

 

times) 

Discharge for 2hrs 

500mA 

300mA 

X axis 

Cycle (times) 

Charge for 6hrs 

200mA 

120mA 

Y axis 

Max capacity (Ah) 

50

th

 times 

2.0Ah 

1.2Ah 

Remark 

In real situation the discharge/ 
charge varies- this test is only for 
reference 

Discharge until protect 

500mA 

300mA 

Charge until max 
capacity 

200mA 

120mA 

*Repeat since 51

 

times 

1

50

100

150

200

250

300

Max capacity (Ah)

2

1.9

1.7

1.5

1.2

1.1

0.9

0

0.5

1

1.5

2

2.5

TBB and TBB4 (2.0Ah) cycle test curve 

1

50

100

150

200

250

300

Max capacity (Ah)

1.2

1.1

0.9

0.8

0.7

0.6

0.5

0

0.2

0.4

0.6

0.8

1

1.2

1.4

TBB2 and TBB4 (1.2Ah) cycle test curve 

Содержание TBB4

Страница 1: ...VERSION E 20200514 TBB4 USERMANUAL ...

Страница 2: ... 1 Warning 3 2 Specifications 4 3 Button Operation 5 4 Indication 5 4 1 Status 5 4 2 Table 5 4 3 Remarks 5 5 Protect 5 6 Maintenance 6 6 1 Storage 6 6 1 Repair 6 6 2 Transportation 6 6 3 Storage 6 7 Appendix 7 7 1 Discharge time curve 7 7 2 Cycle test curve 8 ...

Страница 3: ...r Manual Version E May 2020 3 1 Warning Must follow the rated input voltage Don t discard or expose the products into water or heat source Recycle with certified depots Repair by authorized maintenance centers ...

Страница 4: ...tery capacity 2 0Ah 0 1C discharge 200mA 1 2Ah 0 1C discharge 120mA Input 29 45V DC Output 24VDC 2 0A 24VDC 1 2A Duty cycle 10 2 min on 18 min off Operation temperature 5 45 IP rating Up to IP66W optional Dimension 209 116 60 mm Net weight pc 2 0kg 1 6kg ON OFF switches With ...

Страница 5: ...g 1 sec 1 sec Hi battery 25 Green Long dimming 0 5 sec 4 sec Low battery 25 Orange Long dimming 0 5 sec 4 sec Protection 20 Off Failure Orange Continuous on 4 3 Remarks From Hi charging status around 80 to fully charged in warranty period 90 max capacity it needs around additional 10hrs charging When seeing the failure status indication please liaise with the seller 5 Protect Under below protectio...

Страница 6: ...in V S estimated capacity 100 capacity when shipped out from factory Period including shipping Capacity Status 3 months 79 usable 6 months 58 please charge before use 6 months 58 too long storage period battery capacity harmed Be sure to charge 24hrs every 6 months least 6 1 Repair Same spec dimension lead acid maintenance free battery cell Please consult to the seller 6 2 Transportation By sea or...

Страница 7: ... Discharge current A Y axis Discharge time min Remark In real situation the discharge varies this test is only for reference 1A 2A 3A 4A 5A 6A Time min 37 18 9 6 4 3 0 5 10 15 20 25 30 35 40 TBB2 and TBB4 1 2Ah discharge time curve 1A 2A 3A 4A 5A 6A Time min 89 41 27 19 15 12 0 10 20 30 40 50 60 70 80 90 100 TBB and TBB4 2 0Ah discharge time curve ...

Страница 8: ...th times 2 0Ah 1 2Ah Remark In real situation the discharge charge varies this test is only for reference Discharge until protect 500mA 300mA Charge until max capacity 200mA 120mA Repeat since 51 times 1 50 100 150 200 250 300 Max capacity Ah 2 1 9 1 7 1 5 1 2 1 1 0 9 0 0 5 1 1 5 2 2 5 TBB and TBB4 2 0Ah cycle test curve 1 50 100 150 200 250 300 Max capacity Ah 1 2 1 1 0 9 0 8 0 7 0 6 0 5 0 0 2 0 ...

Отзывы: