User  Manual-MA1_AC  Version 

 

 

 

Version B July 2020 

4  of  19 

 

1.

 

General 

 

About this manual 

1.1

This user manual is provided to the manufacturer of the equipment or system rather than end users. This 
manual provides information needed to install, use and maintain the TiMOTION products. Manufacturers are 
responsible to provide a user guide to the end users using the relevant safety information passed from this 
manual.   
 
This manual contains installation directions as well as technical data for the TiMOTION industrial electric 
linear actuators. Carefully read through each section of the user manual before the equipment is unpacked, 
installed or operated. Please note all the dangers, warnings, cautions and notes stated in this manual. Please 
follow the instructions provided in this manual to ensure safe reliable operation. 

 

 

Target Personnel   

1.2

Please allow qualified mechanical and electrical professionals perform all installation, maintenance and 
replacement of the TiMOTION products. Please keep the products away from people who do not have the 
required experiences or knowledge of the product. 
 

 

Warranty 

1.3

In general, TiMOTION provides a 24-month warranty on Industrial Motion actuators based on the 
manufacturing date. The warranty is valid only if the equipment is properly operated and maintained correctly. 
The application of the product is the responsibility of the buyer. TiMOTION makes no representation or 
warranty as to the suitability of the product for any particular use or purpose. 
       

 

Transport and storage   

1.4

The actuator should only be stored and transported in the original TiMOTION packaging. The temperature 
during transportation and storage must be between -40 to +85° C (-40 to +185° F). Please avoid shocks to 
the package. If the package is damaged, check the actuator for visible damage and notify the carrier and 
TiMOTION. 
 

Содержание MA1_AC

Страница 1: ...User Manual MA1_AC Version Version B July 2020 1 of 19 A User Manual MA1_AC Version...

Страница 2: ...ature 6 1 8 5 2 Installation 7 Mechanical installation 7 2 1 Mounting notice 7 2 1 1 Manual drive operation 8 2 1 2 Electrical installation 9 2 2 Important notice 9 2 2 1 Cable 10 2 2 2 Inrush current...

Страница 3: ...nd of stroke Low LS Lower limit switch is installed in fully retracted end of stroke Mid LS Middle limit switch is installed and the position is set by customer s request N C It is the pin of limit sw...

Страница 4: ...n Target Personnel 1 2 Please allow qualified mechanical and electrical professionals perform all installation maintenance and replacement of the TiMOTION products Please keep the products away from p...

Страница 5: ...ng dismounting the actuator Please read through this user manual before working on the equipment that the actuator is or shall be a part of Adhere to the information contained in this user manual and...

Страница 6: ...can withstand the wear Stop the actuator immediately if anything unusual is observed Ensure there is no side load present on the actuator Only use the actuator within the specified working limits Ref...

Страница 7: ...thout threaded at both ends of the attachments Do not mount the actuator with the pins in different rotated angles this could cause stress on the nut during operation The load should act along the str...

Страница 8: ...en mounting the actuator ensure there is enough space between the rear adapter and any objects This will allow the user override to be operated Use M8 Allen key for both the IP protection screw and th...

Страница 9: ...ply please ensure it is able to withstand the peak of high voltage To reduce the chance of interference refrain from placing signal cables along power cables Use a two wire system to prevent ground lo...

Страница 10: ...with a power cable with without signal wire The standard cable for industrial applications has have flying leads in the end for the user s equipment connections Please refer to the approval drawing of...

Страница 11: ...ctuator starts to work there is an inrush current to the motor that will be less than 0 2 seconds up to four times the rated current Please select a power supply that is able to withstand the inrush c...

Страница 12: ...If your actuator is ordered with customized wiring please contact TiMOTION sales for detail information 2 3 1 Types of output signal In general the MA1 AC cable can have a maximum of 9 pins 5 power w...

Страница 13: ...f 19 2 3 2 Type A Without output signal a Power source 100 240V AC power source b Wiring illustration Power cable Black Grey Brown Blue Green Yellow Actuator housing Black Retract Grey Stretch Brown P...

Страница 14: ...e B POT for output signal a Power source 100 240V AC power source b Wiring illustration Power cable illustration is as the same as 2 3 2 Signal cable illustration is as below Power cable Black Grey Br...

Страница 15: ...3 4 Type C Single Hall a Power source 100 240V AC power source b Wiring illustration Power cable illustration is as the same as 2 3 2 Signal cable illustration is as below Power cable Black Grey Brown...

Страница 16: ...Type D Double Hall a Power source 100 240V AC power source b Wiring illustration Power cable illustration is as the same as 2 3 2 Signal cable illustration is as below Power cable Black Grey Brown Blu...

Страница 17: ...User Manual MA1_AC Version Version B July 2020 17 of 19 3 Product specifications 2D drawings 3 1 3 1 1 With mechanical brake Ball Screw s standard option 3 1 2 Without mechanical brake...

Страница 18: ...User Manual MA1_AC Version Version B July 2020 18 of 19 Ordering key 3 2 Please contact your TiMOTION sales engineer for the latest revision ordering key...

Страница 19: ...ly or the external control unit Customer fuse burned Check the fuse Cable damaged Please contact your TiMOTION sales engineer Excessive power consumption Misalignment or overload in the application Al...

Отзывы: