DESCRIPTION

1. Timken M-Power is an electromechanical automatic lubricator for 

discharging various types of grease and oil. M-Power drives can be
used with 2.03 fl. oz. (60 cc), 4.05 fl. oz. (120 cc), or 8.45 fl. oz. (250 cc)
lubricant cartridges.

2. The unit has two sets of dip switches: 

• The TIME dip switches set the discharge period (1, 3, 6 or 12 months). 
• The VOLUME dip switches may be set to accommodate 2.03 fl. oz. 

(60 cc), 4.05 fl. oz. (120 cc), or 8.45 fl. oz. (250 cc) cartridges.

3. LED performance indicator lights show the operation mode of the unit.

See Installation Instructions, Complete Unit, page 3.

4. The M-Power system consists of a drive end cap, a drive unit, a set of

batteries and a replaceable lubricant cartridge.

Note:

The lubricant cartridge is factory-filled for warranty purposes and

is not refillable.

OUTPUT CHART: DISCHARGE DURATION, AMOUNTS AND CYCLE TIMES

1. Discharge duration periods can be set

using the “TIME” dip switches. M-Power
drive motors can be set to operate with
variable-sized cartridges – 2.03 fl. oz. 
(60 cc), 4.05 fl. oz. (120 cc), or 8.45 fl. oz.
(250 cc). 

2. The output of lubricant depends on the

frequency of operation and the size of the
lubrication cartridge. Settable for approxi-
mately 

1

8

shot per day up to 8 shots per

day.

Table of

Contents

M-Power 300

Product Specs  . . . . . . 1

Installation 
Instructions – 
Lube Cartridge Kit  . . . 2

Installation 
Instructions – 
Complete Unit . . . . . . . 3

Safety Warnings  . . . . 4

Timken M-Power Single-Point Lubricators

M-POWER 300 INSTALLATION INSTRUCTIONS

French and Spanish versions of this instruction sheet are available online at www.timken.com/powerlubricators by clicking on
either the “G-Power Instruction Sheet” or “M-Power Instruction Sheet” links. To locate the MSDS sheet for this product, visit
www.timken.com/powerlubricators and click on the “MSDS” link.

La version en français et en espagnol de cette feuille d’instruction est disponible en ligne à www.timken.com/powerlubricators al
cliquant sur les liens “G-Power Instruction Sheet” ou “M-Power Instruction Sheet.”

Pour trouver la Fiche signalétique sur ce produit visitez www.timken.com/powerlubricators et cliquez su le lien “MSDS.”

Las versiones en francés y español de esta hoja de instrucciones están disponibles en línea en www.timken.com/powerlubricators
al hacer clic, bien sea en los enlaces “Hoja de Instrucciónes para G-Power” o en “Hoja de Instrucciónes para M-Power.”

Para ubicar la Hoja de Datos de Seguridad sobre Materiales (MSDS) para este producto, vaya a www.timken.com/powerlubricators
y haga clic en el enlace “MSDS.”

WARNING:

Follow installation instructions. Prior to installation, ensure that the unit has a free path to discharge lubricant.

Never place near high heat sources or equipment that may produce sparks or flames. Lubricant harmful if swallowed. If
ingested, do not induce vomiting and contact a physician immediately. Avoid direct contact with skin. Contents are under
pressure. Do not remove or open the device when in operation. Do not take apart or attempt to modify the device except for 
replacement as directed in installation instructions. Dispose of used devices properly.