OPERATION
Section 2
22
TIMEWISE 798A
ADJUSTING
PARAMETERS
Throughout this manual you will be directed to alter the values of rally parameters in the
798A. To do so, you must understand how to use the “+ / –” toggle switches as well as the
rotary switch and the
RESET–SHIFT
switch. Read the following information carefully.
Using the
“+ / –” Toggle
Switches
Each of the five “+ / –” adjustment toggle switches alter a rally parameter by a specific
amount:
The
.001
switch increases (+) or decreases (–) the selected parameter .001 unit with each
activation of the switch. If this switch is held in the up or down position for approximately
one second, the parameter will change 12.5 times per second until the toggle handle is
released. This switch is inactive when setting a rally speed.
The
.01
switch increases (+) or decreases (–) the selected parameter .01 unit with each
activation of the switch. If held up or down for approximately one second, the parameter will
change 12.5 times per second. This switch is inactive when setting a rally speed unless
Option 6 is installed and enabled. † See footnote
The
.10
switch increases (+) or decreases (–) the selected parameter .10 unit with each
activation of the switch. If held in the up or down position for approximately one second, the
parameter will change 12.5 times per second. This switch is inactive when setting a rally
speed if you are using the 1 – 399 mph (kph) speed range.
The
1.00
switch increases (+) or decreases (–) the selected parameter 1.00 unit with each
activation of the switch. If held in the up or down position for approximately one second, the
parameter will change 12.5 times per second.
The
10.00
switch increases (+) or decreases (–) the selected parameter 10.00 unit with each
activation of the switch. If held in the up or down position for approximately one second, the
parameter will change 12.5 times per second.
The Rotary
Switch
The rotary switch selects which parameter will be altered when you actuate the “+ / –”
switches. The function of each rotary switch position will be explained throughout this
manual while describing the operation of the 798A.
The 5 o’clock position of the rotary switch does not have an identifying descriptive label.
Instead, an extended indicator line points to a selection of functions below the “+ / –” toggle
switches. These special functions are available for execution whenever the rotary switch is in
the 5 o’clock position. Throughout this manual, the 5 o’clock position of the rotary will be
referred to as either the “5 o’clock” or the “special function” position.
WARNING!
WARNING!
The rotary switch has a rotational stop between the 4 o’clock (
Adjust ORM
) switch position
and 5 o’clock (special function) switch position. Do not force the switch to turn past this
built-in stop! You will break the switch!
†
When the 798A is outfitted with the
High Resolution CASTs
option (identified as Option 6 - installed as a standard feature as of
version 6.000 firmware), the “+ / –”
.01
toggle switch will be active when setting a rally speed. See the option 6 supplement inserted in
the manual for more information. When Option 6 is installed, it can be enabled or disabled – see Option 6 supplement and/or page 98.