WIRING DIAGRAM
Below is the wiring diagram:
© 2020 TimeTec Cloud Sdn Bhd. All rights reserved • 062020
DIMENSIONS
660
12
00
74
5
50
455
1040
295
1600
1020
TROUBLESHOOTING
No
1
2
3
4
Failure descriptions
The mode indica-
tor light does not
respond or the indi-
cation is incorrect.
After swiping the
card, there is only a
speed gate un-
locked.
The barrier doesn’t
close when the
opening delay time
is ended.
When the gate
is self-tested, the
swing arm is not in
the normal closing
position!
Analysis and solution
Check that the control
panel mode indicator wir-
ing is correct or that the
contact is poor.
Check the mode setting
of the master and slave
devices and the 8-core, 2-
core connection lines. See
the wiring diagram for the
specific connection circuit.
Check to see if the opening
delay time is too long or
whether the IR sensor is
covered.
In the process of self-test,
there are obstacles, please
remove the obstacles,
restart the self-test after
power-on!