4. Test the operations of the device after connecting it to
the power supply with the temporary cable. Make sure
that the ground wire of AC power is connected to the
cabinet of the device.
5. Turn on the air switch to test whether the device is work-
ing properly. Wait for 10 seconds for the turnstile to com-
plete the self-test program. At the same time, check if
the indicators work properly. If everything works fine,
you can fasten the ground screw nuts and fix the device.
If an exception occurs, please contact your vendor.
Debugging Functions
Operating instruction
1. After powered on, the LCD screen on the control board
will display the default state showing the current work-
ing mode.
2. There are 4 buttons on the control board:
UP:
to move upwards or increase the value.
DOWN:
to move downwards or decrease the value.
ENT:
to enter a menu setting item or confirm the current
modified value.
ESC:
to return to the previous menu or cancel the cur-
rent operation.
Menus
1. Position adjustment of the swing barrier
• Type: zero (default).
• Left limit, Right limit
2. Passing mode
• Opening mode:
Two-way swipe (default)
• Left free, Right swipe
• Left swipe, Right free
• Two-way free
• Left prohibit, Right swipe
• Left swipe, Right prohibit
• Left prohibit, Right free
• Left free, Right prohibit
• Two-way prohibit
3. Opening duration (Press ‘ENT’ to modify)
After the gate is opened, it will automatically close
if no one passes through within a certain time du-
ration. The default value is 5 seconds. The value
ranges from 2 to 60.
4. Reverse intrusion
Mode: Close the door and voice alarm Voice alarm
only (default) . Turn off reverse detection
5. Trailing alarm detection
• Mode: Turn off trailing detection
• Voice alarm only (default)
• Close the door and voice alarm
6. Opening speed
Speed value: 1~20 (default 1)
7. Closing speed
Speed value: 1~20 (default 1)
8. Swiping mode
• Method: Allow the card to be swiped in the channel
(default).
• Do not allow card swiping in the channel
9. Reset counter
• Reset: Out counter (default)
• Into the counter
• All
10. Gate closing delay time
Time: 0~10 (default 0)
11. Brake unlock mode
Mode: Delay unlock (default)
12. Brake starting angle
Angle: 1~10 (default 3)
13. Fire alarm signal
• Signal: right open
• Left open (default)
• Shut down
14. Volume setting
• Volume: off
• The value ranges from 1 to 16 (default 5).
• 1 is the minimum value; 16 is the maximum value.
15. Audio prompt for gate opening swift
• Enable or not: No (default)
• Yes
16. Infrared anti-pinch
• Mode: Turn off the anti-pinch feature
• Enabling anti-pinch (default)
17. Infrared anti-pinch area
• Area selection:
• Disable during In and out of infrared (default)
• All infrared zone anti-pinch
18. Memory opening
• Whether to open: No (default)
• Yes
19. System working mode
• Mode: working mode (default)
• Test mode • Restore to factory
20. Version number:
Version: V9.0.0