TMS6002
USER MANUAL
Ref : MN06127
Date : 2019-03-27
Issue : A1
Page: 14/18
Tous droits réservés © TimeLink microsystems
3.4.2.
RESTART OR STOP THE EQUIPMENT
These functions allows for securely restart or stop the equipment. The user must first log in as 'root'.
To restart, use the '
reboot
' command; to stop, use '
poweroff
'.
After executing '
poweroff
' the command the equipment can be switched off.
3.4.3.
CHANGE TO USER 'root'
This function allows a user to change its identity to
'root'
.
To do this, type
'
/tools/su'
and enter the 'root' password.
3.5.
SERIAL CONSOLE ACCESS
Access to the system can also be made from the Console port by connecting a terminal emulator software. Use
the following parameters:
•
baud rate 115200
•
8 bits, 1 stop bit, no parity
After logging in with the login/password used to gain SSH access, a shell is opened. The same commands as
those described in 3.4 can be issued.
4.
MONITORING
4.1.
Http server
The http interface is a remote control of the equipment; The integrated http server uses port 80.
The following screenshots give a preview of the pages as they appear in a browser: