1. General Information

These instructions should be read carefully  
and retained for further reference and maintenance.

2. Safety

•  Before installation or maintenance, ensure the 

mains supply to the time switch is switched off 
and the circuit supply fuses are removed or the 
circuit breaker turned off.

•  It is recommended that a qualified electrician is 

consulted or used for the installation of this time 
switch and install in accordance with the current 
IEE wiring and Building Regulations.

•  Check that the total load on the circuit including 

when this time switch is fitted does not  
exceed the rating of the circuit cable,  
fuse or circuit breaker.

All manuals and user guides at all-guides.com

Содержание TS900N

Страница 1: ...I n s t a l l a t i o n O p e r a t i n g I n s t r u c t i o n s 24 Hour Immersion Heater Time Controller Model TS900N All manuals and user guides at all guides com...

Страница 2: ...all gui des co m...

Страница 3: ...y fuses are removed or the circuit breaker turned off It is recommended that a qualified electrician is consulted or used for the installation of this time switch and install in accordance with the cu...

Страница 4: ...g Programme 24 hour Minimum setting interval 15 minutes Minimum ON OFF time between setting 30 minutes Up to 24 ON OFF programmes per day additional pins required Operating temperature 0 C to 40 C CE...

Страница 5: ...cancelling override switch Time indicator Setting pins 24 hour programme ring inner holes ON outer holes OFF Concealed wiring for safety Cover fixing screw Removable cover All manuals and user guides...

Страница 6: ...to be switched ON OFF for maintenance purposes Remove the terminal cover by undoing the fixing screw on the bottom of the time switch Mark the position of the top wall mounting screw and drill the ho...

Страница 7: ...uring not to infringe with any gas water pipes or electrical cables that may be hidden below the surface Insert the rawl plug into the hole Remove the rear cable knock outs if required and pass the 23...

Страница 8: ...all gui des co m...

Страница 9: ...e cable clamps provided to secure the cables Terminate the supply and load cables to the terminal block ensuring correct polarity is observed and that all bare conductors are sleeved Please note the c...

Страница 10: ...erminal E Load Switch Live Brown or Red to Terminal 1 Neutral Blue or Black to Terminal 2 Earth Green Yellow to Terminal E 5 Connection Diagram The terminals are marked as follows on the bottom of the...

Страница 11: ...val is 30 minutes and this can be increased in 15 minute steps Set the correct time of day by rotating the dial clockwise until the correct time is indicated by the Time indicator at the top centre of...

Страница 12: ...operating the override switch in the right hand corner 1 ON O OFF If you use the manual override it will self cancel at the next programmed time The override switch cannot be used within 15 minutes e...

Страница 13: ...e replaced free of charge For the second and third years or any difficulty in the first year telephone the helpline on 020 8450 0515 Note A proof of purchase is required in all cases For all eligible...

Страница 14: ...all gui des co m...

Страница 15: ...ase contact Qualified Customer Support Co ordinators will be on line to assist in resolving your query If you experience problems do not immediately return the unit to the store Telephone the Timeguar...

Отзывы: