background image

3

Learn/Manual Light, 

Blue LED 

Output ON light, 

Red LED 

Automatic/Manual mode button 

Learn button enabling communication between the transmitter  

and receiver, also control button for output in manual mode

Receiver Front View

4. Siting

Receiver

• The TRT037N Receiver should be mounted close to the items it will be 

controlling i.e. boiler, control valves and pump. 

• It should be mounted in a position where its control buttons and indicator 

lights can be easily accessed.

Transmitter

• The TRT037N Transmitter must be sited where it will not be influenced 

by heat sources, for example above a radiator or a television or  
a refrigerator/freezer or in direct sunlight or subjected to draughts.

• The product requires air circulation, so do not position above 

or below shelving or other wall mounted obstacles. 

• It should be mounted approximately 1.5 metres above floor level.

5. Installation 

Receiver

5.1 Ensure the mains supply is switched off and the circuit supply fuses are 

removed or the circuit breaker turned off.

5.2 Remove the wall plate from the receiver unit, by undoing the retaining 

screws, and pivoting the bottom of the unit outwards. The TRT037N 
receiver body can then be lifted off.

Содержание TRT037N

Страница 1: ...I n s t a l l a t i o n O p e r a t i n g I n s t r u c t i o n s Wireless 7 Day Programmable Room Thermostat Model TRT037N...

Страница 2: ...ding Regulations Check that the total load on the circuit including when this programmable room thermostat is fitted does not exceed the rating of the circuit cable fuse or circuit breaker To clean us...

Страница 3: ...llumination Blue LED illuminated on setting for button surrounds and display Installation Type Surface mount with wall plate CE Compliant Dimensions H x W x D 90 x 135 x 30mm Transmitter Front View Di...

Страница 4: ...Transmitter must be sited where it will not be influenced by heat sources for example above a radiator or a television or a refrigerator freezer or in direct sunlight or subjected to draughts The prod...

Страница 5: ...all using the correct mounting screws for the rawl plugs installed The retaining screws which secure the unit to the wall plate should be at the bottom 5 6 Terminate the cables into the terminal block...

Страница 6: ...eries into the unit access the battery compartment located on the left side rear of the unit Use a small flat head screwdriver and release the lug and lever out the battery compartment Insert the 2 x...

Страница 7: ...6 Transmitter Wall Plate Alternate mounting holes Wall plate retaining screws Retaining tabs Mounting holes...

Страница 8: ...e connecting 7 6 Connection Diagram Connect the 230V 50Hz mains supply and load cables to the terminal block which are marked as follows Load Boiler Switch Live Brown or Red to NO 230V 50Hz Mains Supp...

Страница 9: ...required after changing the DIP switch positions The OST Optimal Start Time can also be selected ON or OFF using the DIP switches on the rear of the unit When set to the ON position the heating will...

Страница 10: ...he front of the transmitter and connect the power to the receiver Press the Reset button located beneath the drop down flap Both the Learn Manual light and the Red output light on the receiver will il...

Страница 11: ...ld the Learn button for 10 seconds The blue Learn Manual light will start to flash Press and hold the Select button for 1 second and then at the same time press and hold the Light Frost protection but...

Страница 12: ...ss the Select button once to confirm The year will flash use the Up Down arrow buttons to alter the year and press the Select button once to confirm The month will flash use the Up Down arrow buttons...

Страница 13: ...ler As soon as a Start time begins heat will be demanded until the temperature reaches falls to the selected set point then it will move on to the next Start time temperature period and so on The clos...

Страница 14: ...ht will illuminate Press and hold the Set button for 3 seconds to enter programming mode 10 2 The Day of the week will flash e g Mon use the Up Down arrow buttons if you need to choose a different day...

Страница 15: ...e week and press the Select button once to confirm 10 8 Follow steps 10 3 to 10 7 until you have programmed each day of the week that you require 10 9 Press the Set button three times to exit the prog...

Страница 16: ...copy the programme to e g Tue and press the Select button once to confirm 10 13 Use the Up Down arrow buttons to choose the next day of the week you wish to copy the programme to e g Wed and press the...

Страница 17: ...ction Mode Press the Light Frost Protection button and hold for 3 seconds the button surround and display light will illuminate Frost symbol will continuously flash when frost protection mode is activ...

Страница 18: ...to choose the day you wish to copy the programme to e g Wed The Hand symbol will appear to show the temperature has been manually changed The new set temperature will flash while the change is being m...

Страница 19: ...s responsible for all shipping postage charges outside of the UK All shipping costs are to be paid in advance before a replacement is sent out Heating Symbol The Heating symbol will show when heat is...

Страница 20: ...l csc timeguard com For a product brochure please contact HELPLINE 020 8450 0515 or email helpline timeguard com www timeguard com Qualified Customer Support Co ordinators will be on line to assist in...

Отзывы: