2. Siting
The TRT034 should be located at a position
which eases wiring runs and gives good access
for programming. It should be mounted
approximately 1.5m above floor level.
3. Installation
This product must be installed in accordance with
the appropriate building and wiring regulations.
In all cases if there is a doubt as to how to
proceed with an installation consult a qualified
electrician, your local authority’s building
control department or the Timeguard helpline
(020 8450 0515).
Always isolate the mains supply before
removing the unit from its wall plate.
The TRT034 is designed to be surface mounted
on the supplied wall plate.
Isolate 230VAC mains supply.
Incoming and outgoing cable should be 1.5mmsq.
Contents
TRT034 programmer
TRT034 wall plate
TRT034 instruction leaflet
2 x wall plugs
2 x screws
7 5 - 2
PROGRAM
Connection
pins
Wall plate retaining screws
(at bottom of TRT034)
7 day or
5 + 2 jumper
Press reset after
moving jumper
Fig. 2
Fig. 3
Rear View of TRT034
Back Plate Removed
NC1 NO1
N
L
Alternative
fixing holes
Mount the wall plate in this configuration only
Product
retaining
screws
Terminal for
retaining
continuity
of earth
N
N
CH
230 VAC
OFF ON
NC1 NO1
L
L
CH
Fig. 4
Wiring Diagram
Remove wall plate from unit, by undoing
retaining screws, and pivoting the bottom of the
unit outwards. The unit can then be lifted off.
Pass incoming wires through opening in wall
plate, and fix wall plate securely to the wall,
using screws provided (and wall plugs if
necessary). The screws which hold the product
to the wall plate should point downwards.
Allow sufficient excess cable to wire up the unit,
but not too much to make it difficult to close
the unit to the wall plate.
Connect the conductors to the relevant terminal,
according to the wiring diagram on the wall
plate (or below). Ensure that the curved brass
washer grips the conductor.