background image

2. Siting

The TRT034 should be located at a position 
which eases wiring runs and gives good access 
for programming. It should be mounted 
approximately 1.5m above floor level. 

3. Installation

This product must be installed in accordance with 
the appropriate building and wiring regulations.

In all cases if there is a doubt as to how to 
proceed with an installation consult a qualified 
electrician, your local authority’s building 
control department or the Timeguard helpline
(020 8450 0515).

Always isolate the mains supply before 
removing the unit from its wall plate.

The TRT034 is designed to be surface mounted 
on the supplied wall plate.

Isolate 230VAC mains supply. 

Incoming and outgoing cable should be 1.5mmsq.

Contents

TRT034 programmer
TRT034 wall plate
TRT034 instruction leaflet

2 x wall plugs
2 x screws

7      5 - 2

PROGRAM

Connection
pins

Wall plate retaining screws 

(at bottom of TRT034)

7 day or 

5 + 2 jumper

Press reset after 

moving jumper

Fig. 2

Fig. 3

Rear View of TRT034

Back Plate Removed

NC1 NO1

N

L

Alternative

fixing holes

Mount the wall plate in this configuration only

Product

retaining

screws

Terminal for 
retaining
continuity
of earth

N

N

CH

230 VAC

OFF    ON

NC1 NO1

L

L

CH

Fig. 4

Wiring Diagram

Remove wall plate from unit, by undoing 
retaining screws, and pivoting the bottom of the 
unit outwards. The unit can then be lifted off.

Pass incoming wires through opening in wall 
plate, and fix wall plate securely to the wall, 
using screws provided (and wall plugs if 
necessary). The screws which hold the product 
to the wall plate should point downwards.

Allow sufficient excess cable to wire up the unit, 
but not too much to make it difficult to close 
the unit to the wall plate.

Connect the conductors to the relevant terminal, 
according to the wiring diagram on the wall 
plate (or below). Ensure that the curved brass 
washer grips the conductor.