Diagram B

5. Installation 

•  Ensure the mains supply is switched off and the circuit supply fuses  

are removed or the circuit breaker turned off.

•  An isolating switch should be installed to enable the power to be switched 

ON & OFF for maintenance purposes and to activate the manual/auto 
override function.

•  Remove the top cover of the sensor by twisting the top cover anticlockwise. 

The top cover can now be removed from the sensor body.

Up to 8m Motion Detection

Up to 4m

Presence Detection

Содержание SLW360N

Страница 1: ...I n s t a l l a t i o n O p e r a t i n g I n s t r u c t i o n s 360 Surface Mount PIR Light Controller Model SLW360N...

Страница 2: ...d does not exceed the rating of the circuit cable fuse or circuit breaker Secure device with 10A rated air breaker 3 Technical Specifications 230V AC 50Hz This PIR sensor is of class II construction a...

Страница 3: ...hieved with the unit mounted at the optimum height of 3 metres Careful positioning of the sensor will be required to ensure optimum performance see diagram A B detailing detection range and direction...

Страница 4: ...d off An isolating switch should be installed to enable the power to be switched ON OFF for maintenance purposes and to activate the manual auto override function Remove the top cover of the sensor by...

Страница 5: ...of the PIR sensor Terminate the 230V 50Hz mains supply and load cables into the terminal block ensuring correct polarity is observed and that all bare conductors are sleeved see section 6 Connection...

Страница 6: ...witched Load Light Source Out Switch Live Brown or Red to L1 Neutral Load Blue or Black to N 230V 50Hz Mains Supply Live Supply Brown or Red to L Neutral Supply Blue or Black to N A Loop Terminal is p...

Страница 7: ...The unit will now operate during daytime as well as at night illuminating the lamp for approx 3 seconds each time This allows testing to be carried out to establish whether the sensor is covering the...

Страница 8: ...rotate the control in a clockwise direction until a point is reached where the lamp illuminates 3 Leave the control set at this point In this position the unit should become operative at approximately...

Страница 9: ...R sensor will not operate at all Check that the power is switched ON at the isolation switch Turn OFF the power to the unit and check the wiring connections Check the lamp if it s changeable If the la...

Страница 10: ...cate the unit The detection range varies from day to day The PIR detectors are influenced by climatic conditions The colder the ambient temperature the more effective the sensor will be You may need t...

Страница 11: ...proof of purchase and it will be replaced free of charge For years 2 and 3 or any difficulty in the first year telephone the helpline on 020 8450 0515 Note A proof of purchase is required in all case...

Страница 12: ...csc timeguard com For a product brochure please contact If you experience problems do not immediately return the unit to the store Telephone the Timeguard Customer Helpline Qualified Customer Support...