10. Troubleshooting

Problem

•  Lamp stays ON  
  all the time  
  night and day.

•  The PIR keeps  
  activating for no  
  reason at random.

Solution

Cover the PIR lens with a thick cloth. If the light 

turns OFF, check the detection area for heat or a 
reflective source. 
If the light stays ON, check the wiring (See 

section 5. Installation and Connection).

Turn OFF at the isolation switch. Turn back ON 
again after 30 seconds. Leave for approximately 

15 minutes. If the light activates, check for false 

activation from heat, wind or a reflective source.

Check that the power is switched ON at the 

isolation switch. Turn OFF the power to the unit 

and check the wiring connections. 

Check the lamp (if it’s changeable). 

If the lamp has failed, replace. Ensure the lamp  
is seated correctly in the lamp-holder. 
Note: the unit will not detect through glass.  
(e.g. in a glazed porch).

The level of ambient light in the area may be  

too bight to allow operation at the current  
DUSK setting. 
During the hours of darkness, adjust the  
DUSK control slowly clockwise until  
the lamp illuminates.

•  PIR sensor will not  
  operate at all.

•  PIR sensor will not  
  operate at night.

Содержание SLFM360L

Страница 1: ...I n s t a l l a t i o n O p e r a t i n g I n s t r u c t i o n s 360 Ceiling PIR Light Controller Model SLFM360L ...

Страница 2: ...ircuit cable fuse or circuit breaker 3 Technical Specifications 230V AC 50 Hz Motion Detection Range Up to 6 metres diameter 3m Radius at a 2 5m mounting height This PIR sensor is of class II construction and must not be earthed Detection Angle 360 Maximum Switching Load 2400W Halogen 500W Fluorescent 150W CFL Low Energy LED lamps 10W Lamps max 100W LED lamps 10W 32W max 50W 75W Fan Time ON Adjust...

Страница 3: ... sensor looks ACROSS the likely approach path Avoid positioning the sensor where there are any sources of heat in the detection area extractor fans tumble dryer exhausts etc including opposite any other light sources such as other security lights Reflective surfaces i e pools of water or white painted walls may cause false activation under extreme conditions Less sensitive More sensitive 2 5m Side...

Страница 4: ...5mm diameter Using a pad saw or suitable hole cutter cut out a 75mm diameter hole Pass the 230V 50Hz mains supply and load cables through the hole and prepare for termination Terminate the cables into the terminal block ensuring correct polarity is observed and that all bare conductors are sleeved See below details on connection THERE ARE 2 POSSIBLE CONNECTION SCENARIOS Standard connection 230v Ma...

Страница 5: ...m F Remove the factory fitted bridge wire Connect the 3 core mains supply cable to the terminal block on the unit block as follows NEUTRAL Blue N EARTH Green Yellow LIVE Brown L Connect the load in series with the load supply between L1 and L2 terminals Please note that the function of L1 and L2 can be viewed as a simple switch controlled by the PIR sensor electronics The adjustment knobs located ...

Страница 6: ...setting Lux Dusk Dawn setting D Mains Supply IN 1 Switched Load OUT Factory fitted bridge wire REMOVED Mains Supply IN 1 Switched Load OUT Levering area Levering area Factory fitted bridge wire Locating springs fitted position Locating springs pulled back Sensor Cable damps X2 Locators Wiring cover Time On setting Lux Dusk Dawn setting Mains Supply IN 1 Switched Load OUT Factory fitted bridge wire...

Страница 7: ...ox 5 seconds Start moving again after 2 seconds As you cross each zone the lamp will illuminate Repeat the above walking at various distances and angles to the unit This will help you to confirm the detection pattern 7 Setting Up for Automatic Operation When the walk tests are complete the unit can be adjusted for automatic operation The TIME setting controls how long the unit remains illuminated ...

Страница 8: ...etection in unwanted areas mask the sensor lens using the lens mask sticker supplied See diagram C For your information the centre section of the lens covers short range detection and the outer edge of the lens covers long range Mask the sensor to suit your installation 9 Manual Override Mode The light can be switched ON for longer time periods by use of the Manual Override Mode This can be activa...

Страница 9: ...vates check for false activation from heat wind or a reflective source Check that the power is switched ON at the isolation switch Turn OFF the power to the unit and check the wiring connections Check the lamp if it s changeable If the lamp has failed replace Ensure the lamp is seated correctly in the lamp holder Note the unit will not detect through glass e g in a glazed porch The level of ambien...

Страница 10: ... and re locate the unit The PIR detectors are influenced by climatic conditions The colder the ambient temperature the more effective the sensor will be You may need to make seasonal adjustments to the detector head position to ensure trouble free operation all year round PIR activates during the daytime PIR coverage is poor sporadic Detection range varies from day to day ...

Страница 11: ...h proof of purchase and it will be replaced free of charge For years 2 and 3 or any difficulty in the first year telephone the helpline on 020 8450 0515 Note A proof of purchase is required in all cases For all eligible replacements where agreed by Timeguard the customer is responsible for all shipping postage charges outside of the UK All shipping costs are to be paid in advance before a replacem...

Страница 12: ...il csc timeguard com For a product brochure please contact If you experience problems do not immediately return the unit to the store Telephone the Timeguard Customer Helpline Qualified Customer Support Co ordinators will be on line to assist in resolving your query HELPLINE 020 8450 0515 or email helpline timeguard com www timeguard com ...

Отзывы: