7

• The DUSK control determines the level of darkness required for the unit to start 

operating. The setting is best achieved by the procedure below;

1. Set the DUSK control knob fully anti clockwise. 

2. When the ambient light level reaches the level of darkness at which you wish 

the lamp to become operative (i.e. at dusk) SLOWLY rotate the control in a 
clockwise direction until a point is reached where the lamp illuminates. 

3. Leave the control set at this point.

• At this position the unit should become operative at approximately  

the same level of darkness each evening.

• Observe the operation of the unit. If the unit is starting to operate too early  

(i.e. when it is quite light) adjust the control slightly anti-clockwise.  
 If the unit starts to operate too late (i.e. when it is very dark).  
Adjust the control slightly clockwise. 

• Continue to adjust until the unit operates as desired.

Masking the Sensor Lens

• To restrict the sensor coverage, preventing detection in unwanted areas, mask 

the sensor lens using the masks provided in the accessory pack (See diagram I).

• The top section of the lens covers long range detection, the bottom covers  

short range. Similarly the left and right lens sections cover the left and right 
detection areas respectively.

Содержание MTLW3000

Страница 1: ...I n s t a l l a t i o n O p e r a t i n g I n s t r u c t i o n s 2300W PIR Light Controller Model MTLW3000 White...

Страница 2: ...the rating of the circuit cable fuse or circuit breaker 3 Technical Specifications 230V AC 50 Hz This PIR is of Class ll Construction and must not be earthed Motion Detection Range Up to 12 metres at...

Страница 3: ...ll not detect through glass e g in a glazed porch The sensor is more sensitive to movement ACROSS its field of vision than to movement directly TOWARDS See diagram B Therefore position the unit so tha...

Страница 4: ...en beneath the surface Insert the rawl plugs into the holes Pass the cables through the cable entry points on the wiring box ensuring the grommet s is used to maintain the IP rating of the PIR sensor...

Страница 5: ...e in place Slowly rotate the PIR sensor body downwards and back upwards to double check that no wires are trapped Fully tighten the fixing screw See diagram D Diagram C Diagram E Diagram G Diagram F D...

Страница 6: ...lluminate for approximately 1 minute This indicates the unit is wired correctly and the unit is in Test Mode Adjust the sensor head to the desired direction for best coverage See diagram C Note Anglin...

Страница 7: ...te Repeat the above walking at various angles and distances to the unit This will help you to establish the detection pattern If the detection area is too small for your requirements try angling the s...

Страница 8: ...ximately the same level of darkness each evening Observe the operation of the unit If the unit is starting to operate too early i e when it is quite light adjust the control slightly anti clockwise If...

Страница 9: ...andom Solution The unit may be suffering from false activation Cover the sensor lens completely with a thick cloth This will prevent the sensor from seeing anything If the unit now switches off after...

Страница 10: ...that the unit will not detect through glass e g in a glazed porch The level of ambient light in the area may be too bright to allow operation at the current DUSK setting During the hours of darkness...

Страница 11: ...proof of purchase and it will be replaced free of charge For years 2 and 5 or any difficulty in the first year telephone the helpline on 020 8450 0515 Note A proof of purchase is required in all case...

Страница 12: ...il csc timeguard com For a product brochure please contact If you experience problems do not immediately return the unit to the store Telephone the Timeguard Customer Helpline Qualified Customer Suppo...

Отзывы: