1. General Information
These instructions should be read carefully and retained for further reference
and maintenance.
2. Safety
• Before installation or maintenance, ensure the mains supply to the luminaire
is switched off and the circuit supply fuses are removed or the circuit breaker
turned off.
• It is recommended that a qualified electrician is consulted or used for the
installation of this luminaire and install in accordance with the current
IEE wiring and Building Regulations.
• Check that the total load on the circuit including when this luminaire is fitted
does not exceed the rating of the circuit cable, fuse or circuit breaker.
3. Technical Specifications
• 230V AC 50 Hz
• This Luminaire is of class II construction and must not be earthed
• Lamp Type Supplied:
4W LED
• Energy Efficiency:
Class A
• Energy Usage:
4kWH/1000H (Lamp Supplied)
• Lamp Rating :
60W halogen (max.)
18W compact fluorescent (max.)
5W LED (max.)
• Lumen Output:
320-335lm
• Operating Temperature:
-10° to +40°
• Colour Temperature:
Warm White 2900 – 3200K
• IP44 Rated suitable for restricted external applications
• Detection Angle:
150°
• Detection range:
Up To 8m
• Beam angle:
120°
• On time:
100 seconds
• Lux ON/OFF:
30/60